Traffic convergence after an interface shut/no shut event on a REP ring can take up to 5 minutes. Not all the flows are affected. 5 minutes happen to be the same as mac address-table aging timer.
REP ring with load balancing configuration with interface shut/no shut events in succession
Remove the REP vlan load balancing configuration
Traffic convergence after an interface shut/no shut event on a REP ring can take up to 5 minutes. Not all the flows are affected. 5 minutes happen to be the same as mac address-table aging timer. Even when HFL packets are sent over to all the nodes in the ring, mac flushing might not have happened on the interface events, hence the traffic is blocked upto 5 minutes.