Show cem circuit will be showing L-bit counters, but corresponding controller is not having alarm and in up state.
Removed cable from work card, and restored partially, alarm got cleared on the DS1 controller, but cem circuit shows L-bit in counters. The cable is only partially inserted.
Insert back the cable properly.
This will be misleading to customer, since L-bit corresponds to alarm at controller side, with this issue, it wont report any alarm. This would be fixed and AIS would be reported when Lbit is incremented, for this scenario.