Error message FMFP-3-OBJ_DWNLD_TO_DP_FAILED WRClient download to DP failed is seen when macro auto global processing is enabled. There is no traffic forwarding impact due to these error messages.
+ When we Have a C3650/3850/9k with 2 Layer 3 links to a 6800 switch which also has 2 L3 links we see the error "FMFP-3-OBJ_DWNLD_TO_DP_FAILED WRClient download to DP failed" many times under the following conditions. 1) C3650/3850/9k is running 16.9.4 or above, but problem can be seen also with earlier releases without error log. 2) C3650/3850/9k has "macro auto global processing" applied. 3) Given that the 6800 has the same MAC address on all Layer 3 ports by design then on the C3650/3850/9k the auto smart port feature is writing to and deleting from the Crimson Database the info regarding the MAC seen on each of those 2 layer 3 ports that connect to the 6800. Since the MAC is shown on one port and then shown on the other then this process of write and delete to the database is repeated many times until the MAC entry on the database for the Auto Smart Ports feature gets stuck and we see the error messages.
Workaround #1: On the C3650/3850/9k, remove the "macro auto global processing" from global config mode and reboot the C3650/3850/9k. Workaround #2: + On the C3650/3850/9k side do a shutdown of one of the 2 interfaces that go to the 6807. This is to stop all new processing of the auto smart port feature on the port. + Then on the other side of that link on the 6807 change the MAC on the L3 port. + Then go back to the C3650/3850/9k and do a no shut. + At this point the C3650/3850/9k re-learns the new MAC and we now have 2 different MACs from the 6807 learned on the C3650/3850/9k, hence the auto smart ports feature stops trying to re-program the same MAC. Hence the error message is no longer seen. + Note: After these changes the error message is not seen on the logs anymore after some time however the output of "show platform software wired-client F0" and "show platform software wired-client F1" (F1 is used if you have 2 SUPs) will still show the MAC addresses with the Modify/delete-f status, these are the old entries on the auto smart ports feature that are stuck. If we want to clean the entries then after changing the MACs on the 6807 side we would need a reload on the C3650/3850/9k side. Workaround #3 Configure the following on the uplink ports connected to the 6800 switch: Legacy authentication mode shown in "show running-config: as "no aaa new-model" : "no access-session template" Eedge style authentication mode shown in "show running-config" as "aaa new-model" : "no access-session monitor" This will stop the MAC move from the session monitoring feature on these interfaces. If the MAC move has been previously happening because these commands were not on the uplink ports, and the error messages were displayed then a reload would be required to guarantee a stable system.
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.