This request is to enhance the current L2 CC capabilities : - add verification of hardware layer programming (right now the existing version of L2 CC is verifying the consistency of FMAN layer only) - add L2 CC as a separate new test included in the GOLD diagnostic framework that will be performed on a periodic base and can be disabled if needed (frequency of execution is still TBD) - adding information about L2 CC execution to btrace logs - modify the outputs to make it user-friendly from both a TAC and customer perspective - the outputs should indicate the name of the verified layer and provide information regarding potential inconsistency found example: Consistency Check Status (Forwarding Manager software database ? MATM): Passed Number of inconsistencies found: 0 Consistency Check Status (Hardware programming - FED): Passed Number of inconsistencies found: 0 or Consistency Check Status (Forwarding Manager software database ? MATM): Failed Number of inconsistencies found: 1 Inconsistencies found for following entries: 034a.221b.351f vlan 10 port Gig 1/0/1