Cat9300 stack of switches might encounter a rare condition upon IOS upgrade from 16.09.02 to 16.09.03 in INSTALL mode when STACK-POWER cables are connected but STACK-POWER ports configured as STANDALONE. Anything powered by PoE will go down with power deny and error log: 000589: *Oct 15 16:02:35.337 UTC: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi2/0/13: PD removed 000590: *Oct 15 16:02:35.399 UTC: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi2/0/14: PD removed 000591: *Oct 15 16:02:40.717 UTC: %ILPOWER-7-DETECT: Interface Gi2/0/13: Power Device detected: Cisco PD 000592: *Oct 15 16:02:40.718 UTC: %ILPOWER-5-ILPOWER_POWER_DENY: Interface Gi2/0/13: inline power denied. Reason: insufficient power 000593: *Oct 15 16:02:40.779 UTC: %ILPOWER-7-DETECT: Interface Gi2/0/14: Power Device detected: Cisco PD 000594: *Oct 15 16:02:40.780 UTC: %ILPOWER-5-ILPOWER_POWER_DENY: Interface Gi2/0/14: inline power denied. Reason: insufficient power 000595: *Oct 15 16:02:53.610 UTC: %PLATFORM_FEP-1-FRU_PS_SIGNAL_FAULTY: Switch 2: signal on power supply B is faulty 000596: *Oct 15 16:02:55.718 UTC: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi2/0/13: PD removed 000597: *Oct 15 16:02:55.780 UTC: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi2/0/14: PD removed 000598: *Oct 15 16:03:01.149 UTC: %ILPOWER-7-DETECT: Interface Gi2/0/13: Power Device detected: Cisco PD 000599: *Oct 15 16:03:01.150 UTC: %ILPOWER-7-DETECT: Interface Gi2/0/14: Power Device detected: Cisco PD 000600: *Oct 15 16:03:01.657 UTC: %ILPOWER-5-POWER_GRANTED: Interface Gi2/0/13: Power granted 000601: *Oct 15 16:03:02.608 UTC: %ILPOWER-5-POWER_GRANTED: Interface Gi2/0/14: Power granted F340.26.03-9300-11#show power inline Module Available Used Remaining (Watts) (Watts) (Watts) ------ --------- -------- --------- 1 n/a n/a n/a Interface Admin Oper Power Device Class Max (Watts) --------- ------ ---------- ------- ------------------- ----- ---- Gi1/0/1 static errdisable 0.0 n/a n/a 15.0 Gi1/0/2 auto off 0.0 n/a n/a 60.0 Gi1/0/3 auto off 0.0 n/a n/a 60.0 Gi1/0/4 auto off 0.0 n/a n/a 60.0 Gi1/0/5 auto off 0.0 n/a n/a 60.0 Gi1/0/6 auto off 0.0 n/a n/a 60.0 Gi1/0/7 auto off 0.0 n/a n/a 60.0 Gi1/0/8 static off 0.0 n/a n/a 60.0 Gi1/0/9 auto off 0.0 n/a n/a 60.0 Gi1/0/10 auto off 0.0 n/a n/a 60.0 Gi1/0/11 auto off 0.0 n/a n/a 60.0 Gi1/0/12 auto off 0.0 n/a n/a 60.0 Gi1/0/13 auto power-deny 0.0 n/a n/a 60.0 <<<<< Both Switches Down Gi1/0/14 auto power-deny 0.0 n/a n/a 60.0 <<<<< Both Switches Down Gi1/0/15 auto off 0.0 n/a n/a 60.0 Gi1/0/16 auto off 0.0 n/a n/a 60.0 Gi1/0/17 auto off 0.0 n/a n/a 60.0 Gi1/0/18 auto off 0.0 n/a n/a 60.0 Gi1/0/19 auto off 0.0 n/a n/a 60.0 Gi1/0/20 auto off 0.0 n/a n/a 60.0 Gi1/0/21 auto off 0.0 n/a n/a 60.0 Gi1/0/22 auto off 0.0 n/a n/a 60.0 Gi1/0/23 static off 0.0 n/a n/a 30.0 Gi1/0/24 auto off 0.0 n/a n/a 60.0 Module Available Used Remaining (Watts) (Watts) (Watts) ------ --------- -------- --------- 2 n/a n/a n/a Interface Admin Oper Power Device Class Max (Watts) --------- ------ ---------- ------- ------------------- ----- ---- Gi2/0/1 auto off 0.0 n/a n/a 60.0 Gi2/0/2 auto off 0.0 n/a n/a 60.0 Gi2/0/3 auto off 0.0 n/a n/a 60.0 Gi2/0/4 auto off 0.0 n/a n/a 60.0 Gi2/0/5 auto off 0.0 n/a n/a 60.0 Gi2/0/6 auto off 0.0 n/a n/a 60.0 Interface Admin Oper Power Device Class Max (Watts) --------- ------ ---------- ------- ------------------- ----- ---- Gi2/0/7 auto off 0.0 n/a n/a 60.0 Gi2/0/8 auto off 0.0 n/a n/a 60.0 Gi2/0/9 auto off 0.0 n/a n/a 60.0 Gi2/0/10 auto off 0.0 n/a n/a 60.0 Gi2/0/11 auto off 0.0 n/a n/a 60.0 Gi2/0/12 auto off 0.0 n/a n/a 60.0 Gi2/0/13 auto power-deny 0.0 n/a n/a 60.0 <<<<< Both Switches Down Gi2/0/14 auto power-deny 0.0 n/a n/a 60.0 <<<<< Both Switches Down Gi2/0/15 auto off 0.0 n/a n/a 60.0 Gi2/0/16 auto off 0.0 n/a n/a 60.0 Gi2/0/17 auto off 0.0 n/a n/a 60.0 Gi2/0/18 auto off 0.0 n/a n/a 60.0 Gi2/0/19 auto off 0.0 n/a n/a 60.0 Gi2/0/20 auto off 0.0 n/a n/a 60.0 Gi2/0/21 auto off 0.0 n/a n/a 60.0 Gi2/0/22 auto off 0.0 n/a n/a 60.0 Gi2/0/23 auto off 0.0 n/a n/a 60.0 Gi2/0/24 auto off 0.0 n/a n/a 60.0
Cat9300 stack of switches IOS upgrade from 16.09.02 to 16.09.03 in INSTALL mode STACK-POWER cables are connected STACK-POWER ports configured as STANDALONE
-Power Cycle -If device equipped with two power supply in my test I unplugged one cable wait for 10sec plugged back in and PoE will turn back on -If device had only one PS in my case I add another one and once power apply PoE turn back on
To prevent this issue if STACK-POWER cables are installed make sure that STACK-POWER ports are NOT in STANDALONE mode WRONG: F340.26.03-9300-11#sh stack-power Power Stack Stack Stack Total Rsvd Alloc Sw_Avail Num Num Name Mode Topolgy Pwr(W) Pwr(W) Pwr(W) Pwr(W) SW PS -------------------- ------ ------- ------ ------ ------ ------ ----- ---- Powerstack-1 SP-PS Stndaln 2200 0 349 1851 1 2 Powerstack-11 SP-PS Stndaln 2200 0 247 1953 1 2 CORRECT F340.26.03-9300-11#sh stack-power Power Stack Stack Stack Total Rsvd Alloc Sw_Avail Num Num Name Mode Topolgy Pwr(W) Pwr(W) Pwr(W) Pwr(W) SW PS -------------------- ------ ------- ------ ------ ------ ------ ----- ---- Powerstack-1 SP-PS Ring 4400 30 596 3774 2 4 This seems to only affect upgrade from 16.9.2 to 16.9.3 in other words upgrade from 16.9.2 to 16.9.4 or 16.9.3 to 16.9.4 replicated in the lab was fine.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.