Issue present when remove custom diagnostic schedules Issue seen on cat9300 and cat9400 As soon as the schedules are removed the standby switch reloads or the standby supervisor reloads of a 9400 chassis due to configuration mismatch "no diagnostic schedule switch [switch] test non-disruptive [time]" %PARSER-5-CFGLOG_LOGGEDCMD: User:bsadmin logged command:no diagnostic schedule switch 1 test non-disruptive weekly Tuesday 7:00 %RF-5-RF_RELOAD: Peer reload. Reason: Configuration mismatch %HMANRP-5-CHASSIS_DOWN_EVENT: Chassis 2 gone DOWN! %REDUNDANCY-3-STANDBY_LOST: Standby processor fault (PEER_NOT_PRESENT) %REDUNDANCY-3-STANDBY_LOST: Standby processor fault (PEER_DOWN) %REDUNDANCY-3-STANDBY_LOST: Standby processor fault (PEER_REDUNDANCY_STATE_CHANGE)