Loading...
Loading...
POE stopped from switch towards PD devices. Logs: 004097: May 23 14:48:17.050 SGT: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi1/0/7: PD removed 004098: May 23 14:48:17.053 SGT: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi1/0/7: PD removed 004100: May 23 14:48:22.258 SGT: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi1/0/7: PD removed Debugs: 2019/06/19 08:15:16.545 [redearth]: [19924]: UUID: 0, ra: 0 (ERR): For message app_id: 3, sub_addr: 0, is CMD: 1, len: 2 2019/06/19 08:15:16.545 [redearth]: [19924]: UUID: 0, ra: 0 (ERR): Invalid header frame #59603: 0x0b 0xbc 2019/06/19 08:15:16.545 [redearth]: [19924]: UUID: 0, ra: 0 (ERR): invalid frame 2019/06/19 08:15:16.444 [redearth]: [19924]: UUID: 0, ra: 0 (ERR): msg: 0x32 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 2019/06/19 08:15:16.444 [redearth]: [19924]: UUID: 0, ra: 0 (ERR): For message app_id: 3, sub_addr: 0, is CMD: 1, len: 2 2019/06/19 08:15:16.444 [redearth]: [19924]: UUID: 0, ra: 0 (ERR): Invalid header frame #59602: 0x30 0x81 2019/06/19 08:15:16.444 [redearth]: [19924]: UUID: 0, ra: 0 (ERR): out of sequence 2019/06/19 08:15:16.344 [redearth]: [19924]: UUID: 0, ra: 0 (ERR): msg: 0x32 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
when the device recieved a large amount of Interupts from the PD
Reload the device.
Click on a version to see all relevant bugs