An ASR920 or an ASR903 with RSP2 may see repeat multi-bit memory errors in its handoff FPGA when the Flexible Netflow (FNF) cache's maximum size is exceeded. Eg: %IOSXE-3-PLATFORM: SIP0: cylon_mgr: Handoff FPGA: DDR3 ECC Multi Bit error occurred %HANDOFF_FUD-6-FPGA_INTERRUPTS_ERROR: SIP0: cylon_mgr: Handoff FPGA encountered interrupts which are not getting cleared In addition, the below command will show historical multi-bit errors: ROUTER# show platform hardware pp active fpga interrupt misc | i mbiterr ddr3_ecc_mbiterr_int: 4 Due to the multi-bit errors in the FPGA, functionality that relies on this FPGA (eg: hardware timers for BFD) can be impacted. In the case of BFD, it can tear down at random and bring down any protocols that depend on it, like OSPF.
This issue is triggered if the router has Flexible Netflow (FNF) configured and internal flow ID's have exceeded the maximum cache size hard-coded in software. This will cause the FPGA to try to access uninitialized memory locations and interpret this as an MBE (multi-bit error) in memory. An MBE is a hardware check to see if multiple binary bits in a value of memory are incorrect and can often be used to verify a hardware failure, but because this check is being ran on uninitialized memory, it is not valid in this case.
=== Option 1 === Remove FNF config. This is likely the most straightforward option with the least compromises in most cases. === Option 2 === If BFD is misbehaving due to the FPGA being in an unpredictable state due to this issue, BFD timers can be offloaded from hardware to software as follows. Note: The first command is a global config, and the last command needs to be applied per-interface. ROUTER(config)#platform bfd-offload-timer 200000 ROUTER(config)# int gig x/x ROUTER(config-if)#interval min-tx 300 min-rx 300 multiplier 3 === Option 3 === In IOS images with the fix for CSCvj67000, routers will now properly reload in the event of any general MBE error, whether hardware-related or due to a software bug. Although a reload is not ideal, it will clear the state of the FPGA and allow it to function normally for a period of time. === Option 4 === The router can be reloaded manually, which will also temporarily clear the FPGA and allow it to function normally.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.