PTP does not work on 1G uplink on WS-C3650-24PDM due to high neighbor propagation delay. It's higher than "ptp neighbor-propagation-delay-threshold" should allow and the port stays "dot1as incapable". Switch1Bottom#show platform software fed sw ac ifm mappings | b GigabitEthernet1/1/2 GigabitEthernet1/1/2 0x20 0 0 0 1 0 1 0 26 26 NIF Y TenGigabitEthernet1/1/3 0x21 0 0 0 2 0 2 0 27 27 NIF Y TenGigabitEthernet1/1/4 0x22 0 0 0 3 0 3 0 28 28 NIF Y Switch1Bottom#show platform software fed switch active ptp if-id 0x20 Displaying port data for if_id 20 ======================================= Port Mac Address BC:26:C7:52:47:1A Port Clock Identity BC:26:C7:FF:FE:52:47:00 Port number 26 PTP Version 2 domain_value 0 Profile Type: : DOT1AS dot1as capable: FALSE <<< dot1as capable sync_recpt_timeout_time_interval 375000000 nanoseconds sync_interval 125000000 nanoseconds neighbor_rate_ratio 1.000004 neighbor_prop_delay 281474976710507 nanoseconds <<<<<< sky high neighbor prop delay peer_mean_path_delay 0 nanoseconds compute_neighbor_rate_ratio: TRUE compute_neighbor_prop_delay: TRUE port_enabled: TRUE ptt_port_enabled: TRUE current_log_pdelay_req_interval 0 pdelay_req_interval 0 nanoseconds allowed_pdelay_lost_responses 2 is_measuring_delay : TRUE neighbor_prop_delay_threshold 0 nanoseconds Port state: : DISABLED sync_seq_num 49653 delay_req_seq_num 7129 num sync messages transmitted 0 num sync messages received 0 num followup messages transmitted 0 num followup messages received 0 num pdelay requests transmitted 199 num pdelay requests received 199 num pdelay responses transmitted 199 num pdelay responses received 199 num pdelay followup responses transmitted 199 num pdelay followup responses received 199
1G uplink on WS-C3650-24PDM SFP tested: GLC-SX-MM CAB-SFP-50CM
Manually configure the latency using the below command. test platform software fed switch active ptp if-id latency Eg. "test platform software fed switch active ptp if-id 0x20 latency 100" Note: This value will get reset whenever the link flaps or the switch reboots, hence it has to be set again.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.