======================================================================= Note- A. It is not necessarily a defect/malfunction. But we notice a few interesting behaviors due to advanced booting nature of H/W version 2.0 Cat9300 switches, this CDTES is to track that down. B. It is very specific to stack with mixed hardware versions, specially V01 and V02. C. None of the two issues (explained below) will appear during regular run-time/reload/power cycle of stack. It is seen ONLY once during upgrade/downgrade and that too at specific conditions mentioned below, no major functional loss/impact expected. ======================================================================= Conditions- (Both conditions should be met) ------------------------------------------------------- C9300 stack with mixed H/W version- say V01 and V02 Upgrading/downgrading between codes that need microcode change on V01 switches but NOT on V02. Example- 16.6.x to 16.9.2(and below)/16.6.x to 16.10.1a Observation#1 ========================= Switch with HW V02 does not go through microcode change process (which takes about 5-6 mins) in certain upgrade/downgrade scenarios, whereas H/W V01 switch does. As a result, V02 switch boot 5-6 mins faster than V01 in such cases and becomes master, irrespective of switch priority settings in configuration. The issue won't be seen during regular reload/power cycle OR even upgrade/downgrade between codes, where micro code upgrade is not needed for V01 switches as well (say between 16.6.4 and 16.6.5). Observation#2 ========================= In below scenario, stack-split (this is when two members in same stack are both incorrectly elected as active) happens during upgrade/downgrade between versions that triggers microcode change on V01 switches but not on V02. Here, all the H/w version 02 switches don't have direct connection between them, some of them are connected through V01. When version 02 switches boot faster, they wait past 120 seconds (version 1.0 switches take approx. 5-6 minutes extra) and start electing mater. In this case, switch1-2 can't see switch 5 during stack master election, since sw4 and 8 are still booting at that time(due to microcode upgrade/downgrade). Hence, stack-split happens. Switch1 HW V02 Switch2 HW V02 Switch4 HW V01 Switch5 HW V02 Switch8 HW V01 ******************************************* How do you check the H/W version- "show switch", field is "H/W Version".
NOTE- None of these two issues will be seen, during regular reload/power cycle of stack. It is seen once during upgrade/downgrade only and that too at specific condition mentioned below. Conditions- (Both conditions should be met) ================================== C9300 stack with mixed H/W version- say V01 and V02 Upgrading/downgrading between codes that need microcode change as well on V01 switches.
Reload the stack once more after upgrade/downgrade is completed, that way stack master is elected based on configured switch priority settings. To avoid split stack situation, build the mixed stack such a way that all HW v02 switches have at least one stack-cable going to other version 2. Example- Switch1 ? HW2 Switch2 ? HW2 Switch3 ? HW2 Switch4 ? HW2 Switch5 ? HW2 Switch6 ? HW2 Switch7 ? HW1 Switch8 ? HW1
This issue is the result of an automatic firmware upgrade/downgrade that is bundled into certain IOS-XE software upgrades/downgrades of HW V01 Catalyst 9300 series switches. Since the software upgrade/downgrade of HW V02 Catalyst 9300 series switches in the same scenarios does not include this automatic firmware upgrade/downgrade, the HW V02 Catalyst 9300 series switches boot up quicker. This can cause incorrect stack active switch election in some cases. This issue only applies to install mode and not to bundle mode IOS-XE software upgrade/downgrades. - Downgrading from 16.9.x or higher to a 16.6.X or lower image may experience this issue. - Upgrading to an image between 16.6.x & 16.9.2, 16.10.1 may experience this issue. - Upgrading to image 16.9.3, 16.10.2 or higher will not have this issue. - Downgrading/Upgrading between any images that are 16.9.3, 16.10.1e, 16.10.2 or higher will not have this issue.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.