OPERATIONAL DEFECT DATABASE
...

...
When management server connected to mgmt0 interface of a leaf via Fast Ethernet (100Mbs). show interface output shows a correct speed, but SNMP walk outputs shows a wrong speed 1GBs mgmt0 is up admin state is up, Hardware: GigabitEthernet, address: X.X.X Internet Address is x.x.x.x MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, medium is broadcast Port mode is routed full-duplex, 100 Mb/s <<<<<<<<<<< Beacon is turned off Auto-Negotiation is turned on [~]$ snmpwalk -v3 -l authPriv -u -a SHA -A -x AES -X X.X.X.X IF-MIB::ifIndex.ZZZZ = INTEGER: ZZZZ IF-MIB::ifDescr.ZZZZ = STRING: mgmt0 IF-MIB::ifType.ZZZZ = INTEGER: ethernetCsmacd(6) IF-MIB::ifMtu.ZZZZ = INTEGER: 1500 IF-MIB::ifSpeed.ZZZZ = Gauge32: 1000000000 <<<<<<<<<<<<<< ç
a device is connected to a management port of a leaf with a speed 100MB/s
N/A Cosmetic issue
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.