Sensors are not present in this output and cannot be polled via SNMP. Switch#show inventory raw | i Sen NAME: "Switch 1 - Inlet Temp Sensor", DESCR: "Switch 1 - C9300-48T - Temp Inlet Sensor 0" NAME: "Switch 1 - Outlet Temp Sensor", DESCR: "Switch 1 - C9300-48T - Temp Outlet Sensor 1" NAME: "Switch 1 - HotSpot Temp Sensor", DESCR: "Switch 1 - C9300-48T - Temp HotSpot Sensor 2" Switch# Switch#show interface transceiver If device is externally calibrated, only calibrated values are printed. ++ : high alarm, + : high warning, - : low warning, -- : low alarm. NA or N/A: not applicable, Tx: transmit, Rx: receive. mA: milliamperes, dBm: decibels (milliwatts). Optical Optical Temperature Voltage Current Tx Power Rx Power Port (Celsius) (Volts) (mA) (dBm) (dBm) --------- ----------- ------- -------- -------- -------- Te1/1/1 31.2 3.30 6.0 -2.2 -2.2 Te1/1/2 28.5 3.31 5.7 -2.0 -2.0 Switch Ports Model SW Version SW Image Mode ------ ----- ----- ---------- ---------- ---- * 1 62 C9300-48T 16.6.5 CAT9K_IOSXE BUNDLE Configuration register is 0x102 SnmpWalk.exe -r:10.6.1.6 -v:2 -c:TEST -os:1.3.6.1.2.1.47.1.1.1.1.7 -op:1.3.6.1.2.1.47.1.1.1.1.8 OID=.1.3.6.1.2.1.47.1.1.1.1.7.1, Type=OctetString, Value=c93xx Stack OID=.1.3.6.1.2.1.47.1.1.1.1.7.1000, Type=OctetString, Value=Switch 1 OID=.1.3.6.1.2.1.47.1.1.1.1.7.1001, Type=OctetString, Value=StackPort1/1 OID=.1.3.6.1.2.1.47.1.1.1.1.7.1002, Type=OctetString, Value=StackPort1/2 OID=.1.3.6.1.2.1.47.1.1.1.1.7.1006, Type=OctetString, Value=Switch 1 - Power Supply A Container OID=.1.3.6.1.2.1.47.1.1.1.1.7.1007, Type=OctetString, Value=Switch 1 - Power Supply B Container OID=.1.3.6.1.2.1.47.1.1.1.1.7.1008, Type=OctetString, Value=Switch 1 - RPS Container OID=.1.3.6.1.2.1.47.1.1.1.1.7.1009, Type=OctetString, Value=Switch 1 - Fan 1 Container OID=.1.3.6.1.2.1.47.1.1.1.1.7.1010, Type=OctetString, Value=Switch 1 - Fan 2 Container OID=.1.3.6.1.2.1.47.1.1.1.1.7.1011, Type=OctetString, Value=Switch 1 - Fan 3 Container OID=.1.3.6.1.2.1.47.1.1.1.1.7.1012, Type=OctetString, Value=Switch 1 - Inlet Temp Sensor OID=.1.3.6.1.2.1.47.1.1.1.1.7.1013, Type=OctetString, Value=Switch 1 - Outlet Temp Sensor OID=.1.3.6.1.2.1.47.1.1.1.1.7.1014, Type=OctetString, Value=Switch 1 - HotSpot Temp Sensor OID=.1.3.6.1.2.1.47.1.1.1.1.7.1015, Type=OctetString, Value=Switch 1 - Power Supply A OID=.1.3.6.1.2.1.47.1.1.1.1.7.1016, Type=OctetString, Value=Switch 1 - Power Supply B OID=.1.3.6.1.2.1.47.1.1.1.1.7.1017, Type=OctetString, Value=Switch 1 - FAN - T1 1 OID=.1.3.6.1.2.1.47.1.1.1.1.7.1018, Type=OctetString, Value=Switch 1 - FAN - T1 2 OID=.1.3.6.1.2.1.47.1.1.1.1.7.1019, Type=OctetString, Value=Switch 1 - FAN - T1 3 OID=.1.3.6.1.2.1.47.1.1.1.1.7.1060, Type=OctetString, Value=Switch 1 Fixed Module 0 OID=.1.3.6.1.2.1.47.1.1.1.1.7.1061, Type=OctetString, Value=Switch 1 Slot 1 FRULink Container
Cat9k running 16.6.5 release.
N/A The issue is not present on 16.9 and 16.10 trains
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.