With interface being 'Admin-Shut' remote end will show link-status as 'Up'. This is specific to 2x100G IM. Not applicable for other ethernet IMs. This can be seen with 16.10.x, 16.11.1 releases (wherein 2x100G IM is supported).
When 2x100G port side is admin-shut, remote end (be it another 2x100G or any other 100g port-type) will report link status as 'UP'. This is due to the laser not turned off, at 2x100G local end.
NIL
Due to laser not being turned off even with 'Admin shutdown' of the interface/port, this lead to peer to report link status as UP still.