OPERATIONAL DEFECT DATABASE
...

...
vPC domain id : 12 Peer status : peer adjacency formed ok vPC keep-alive status : Suspended (UNUSABLE VRF) Configuration consistency status : success Per-vlan consistency status : success Type-2 consistency status : failed Type-2 inconsistency reason : SVI type-2 configuration incompatible vPC role : primary Number of vPCs configured : 1 Peer Gateway : Enabled Dual-active excluded VLANs : - Graceful Consistency Check : Enabled Auto-recovery status : Disabled Delay-restore status : Timer is off.(timeout = 30s) Delay-restore SVI status : Timer is off.(timeout = 10s) Operational Layer3 Peer-router : Disabled
VPC environment. VPC PKA is using "vrf management" Having a vrf with naming using prefix/sufix management Removing the said VRF.
no workaround
BRU-N9K3-1# show vrf VRF-Name VRF-ID State Reason CLUK10618 3 Up -- default 1 Up -- management 2 Up -- vxlan-astepkin 4 Up -- BRU-N9K3-1# BRU-N9K3-1# BRU-N9K3-1# BRU-N9K3-1# conf t Enter configuration commands, one per line. End with CNTL/Z. BRU-N9K3-1(config)# vrf context CLUK10618 management vxlan-astepkin BRU-N9K3-1(config)# vrf context management-111 BRU-N9K3-1(config-vrf)# BRU-N9K3-1(config-vrf)# BRU-N9K3-1(config-vrf)# sh vrf VRF-Name VRF-ID State Reason CLUK10618 3 Up -- default 1 Up -- management 2 Up -- management-111 5 Up -- BRU-N9K3-1(config-vrf)# BRU-N9K3-1(config-vrf)# BRU-N9K3-1(config-vrf)# BRU-N9K3-1(config-vrf)# no vrf context m management management-111 BRU-N9K3-1(config-vrf)# no vrf context management % Invalid command BRU-N9K3-1(config-vrf)# no vrf context management-111 BRU-N9K3-1(config)# show vpc Legend: (*) - local vPC is down, forwarding via vPC peer-link vPC domain id : 12 Peer status : peer adjacency formed ok vPC keep-alive status : Suspended (UNUSABLE VRF) Configuration consistency status : success Per-vlan consistency status : success Type-2 consistency status : failed Type-2 inconsistency reason : SVI type-2 configuration incompatible vPC role : primary Number of vPCs configured : 1 Peer Gateway : Enabled Dual-active excluded VLANs : - Graceful Consistency Check : Enabled Auto-recovery status : Disabled Delay-restore status : Timer is off.(timeout = 30s) Delay-restore SVI status : Timer is off.(timeout = 10s) Operational Layer3 Peer-router : Disabled vPC Peer-link status --------------------------------------------------------------------- id Port Status Active vlans -- ---- ------ ------------------------------------------------- 1 Po12 up 1,5-7,10,19,25,71,90,121-125,141-152,163-166,168, 170-171,173,176,178-179,181,221,224,300,314-316,3 30,335,345,360-362,370,380,385,391-394,400,406,42 6,432,440-441,453-454,460-464,468-470,472,818-819 ,983,996,1000-1002,1234,1321,2100-2114,2300-2309, 2389-2390,2500-2503,2931,2950,2990,3579,3587,3890 ... vPC status ---------------------------------------------------------------------------- Id Port Status Consistency Reason Active vlans -- ------------ ------ ----------- ------ --------------- 104 Po104 up success success 1000-1002,2389 -2390 Please check "show vpc consistency-parameters vpc " for the consistency reason of down vpc and for type-2 consistency reasons for any vpc. BRU-N9K3-1(config)# BRU-N9K3-1(config)# BRU-N9K3-1(config)# BRU-N9K3-1(config)# BRU-N9K3-1(config)# show vrf VRF-Name VRF-ID State Reason CLUK10618 3 Up -- default 1 Up -- management 2 Up --
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.