- Device running in Client mode , domain name TEST , version 2. - After upgrade ,VTP configuration lost, falling back to version 1
- Upgrade from 6.2(16) to 7.3(0)DX(1) - Both Disruptive ISSU & Cold boot sees the same behavior. - VTP version 1/2
Follow supported Non-disruptive ISSU path
Device configured as below Switch-VTP# sh vtp status VTP Status Information ---------------------- VTP Version : 2 (capable) Configuration Revision : 4 Maximum VLANs supported locally : 1005 Number of existing VLANs : 8 VTP Operating Mode : Client VTP Domain Name : TEST VTP Pruning Mode : Disabled (Operationally Disabled) VTP V2 Mode : Enabled VTP Traps Generation : Disabled MD5 Digest : 0xC1 0x1E 0x8A 0x73 0x45 0xA8 0xBF 0xE4 Configuration last modified by 10.122.190.100 at 12-12-08 21:39:57 VTP version running : 2 After the upgrade ================== Switch-VTP# show vtp status VTP Status Information ---------------------- VTP Version : 3 (capable) Configuration Revision : 0 Maximum VLANs supported locally : 1005 Number of existing VLANs : 5 VTP Operating Mode : Server VTP Domain Name : VTP Pruning Mode : Disabled (Operationally Disabled) VTP V2 Mode : Disabled VTP Traps Generation : Disabled MD5 Digest : 0x57 0xCD 0x40 0x65 0x63 0x59 0x47 0xBD 0x56 0x9D 0x4A 0x3E 0xA5 0x69 0x35 0xBC Configuration last modified by 0.0.0.0 at 12-12-08 22:10:03 Local updater ID is 10.122.190.100 on interface mgmt0 (first L3 interface found) VTP version running : 1 - Version falls back from version 2 to version 1 - VTP Domain name configuration missing. - VTP mode changes from Client to Server - Changing the VTP datafile to a non-default file also doesnt help. - Event-history shows the below 2 errors. Switch-VTP# show vtp internal event-history errors 1) Event:E_DEBUG, length:92, at 226024 usecs after Fri Dec 12 22:10:03 2008 [102] vtp_utils.c/vtp_receive_app_config():3892 VTP instance 1 not supported in version 1/2 2) Event:E_DEBUG, length:93, at 213561 usecs after Fri Dec 12 22:10:03 2008 [102] vtp_restore_pss_data.c/vtp_restore_from_saved_config():527 runtime pss config was empty Hardware : Nexus 7700 with N77-SUP2E Software : 6.2(16)
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.