The command "negotiation auto" is accepted on tengig fiber link, when the auto neg is not supported. The command gets accepted only when the bandwidth is configured to be 1G. interface TenGigabitEthernet0/1/0 bandwidth 1000000 load-interval 30 negotiation auto cdp enable Due to this the link get in status "up" and protocol "down" state. if we change the configuration to ?negotiation auto? the protocol goes in down state, with below mentioned log: %IOSXE_SPA-6-UPDOWN:; Interface TenGigabitEthernet0/1/0, link down due to local fault %LINK-3-UPDOWN:Interface TenGigabitEthernet0/1/0, changed state to down
Interface bandwidth should be configured 1gig
Remove the bandwidth command, and keep the default badwith of 10 gig.