9300 running HSRP may fail to dynamically learn the HSRP vMAC after an HSRP failover/switchover. The HSRP vMAC will be dynamically learned on the 9300 when the HSRP active is on another device, when failover/switchover occurs the HSRP vMAC will be statically learned. Upon next failover, the HSRP vMAC should be dynamically learned but fails to get programmed on the 9300. As a result, pings, etc. to the HSRP vIP address will fail.
9300 running 16.6.1, 16.6.2, 16.6.3 using HSRP may run into the issue after a switchover in which the HSRP vMAC goes from dynamically to statically learned, and then back to statically learned.
Issue is fully resolved in the upcoming release of IOS XE 16.6.X, 16.6.4 If the 9300 is reloaded, this will temporarily clear the issue. However if the same failover events were to occur on the 9300, in which the HSRP vMAC is dynamically learned, then statically learned, and then back to dynamically learned, the issue may resurface.