'%NGWC_PLATFORM_FEP-1-FRU_PS_SIGNAL_FAULTY' message is not output on C3850 even though power cable is removed. If we try same operation again,'%NGWC_PLATFORM_FEP-1-FRU_PS_SIGNAL_FAULTY' message is output. This is observed after system reload.
03.07.02E
This problem is observed once after system reload. '%NGWC_PLATFORM_FEP-1-FRU_PS_SIGNAL_FAULTY' message is output 2nd removal or later.
When the power supply cable is removed from a FEP then it is expected behavior to get the log message: "%NGWC_PLATFORM_FEP-1-FRU_PS_SIGNAL_FAULTY". This message suggests that "SIGNAL on power supply is faulty" and NOT that the power supply itself is faulty. This log message should be coming when we remove the power supply cable for the first time after reload of the switch.