Rcv-Err and IntMacRx-Er errors incrementing: N9K# show interface counters errors | exclude "\ 0\ *0\ *0\ *0\ *0\ *0"| ex "\ 0\ *--\ *0\ *0\ *0" -------------------------------------------------------------------------------- Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize OutDiscards -------------------------------------------------------------------------------- Eth2/1 0 0 0 12118 0 0 -------------------------------------------------------------------------------- Port Single-Col Multi-Col Late-Col Exces-Col Carri-Sen Runts -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Port Giants SQETest-Err Deferred-Tx IntMacTx-Er IntMacRx-Er Symbol-Err -------------------------------------------------------------------------------- Eth2/1 0 -- 0 0 12118 0
Rcv-Err and IntMacRx-Er errors incrementing: N9K# show interface counters errors | exclude "\ 0\ *0\ *0\ *0\ *0\ *0"| ex "\ 0\ *--\ *0\ *0\ *0" -------------------------------------------------------------------------------- Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize OutDiscards -------------------------------------------------------------------------------- Eth2/1 0 0 0 12118 0 0 -------------------------------------------------------------------------------- Port Single-Col Multi-Col Late-Col Exces-Col Carri-Sen Runts -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Port Giants SQETest-Err Deferred-Tx IntMacTx-Er IntMacRx-Er Symbol-Err -------------------------------------------------------------------------------- Eth2/1 0 -- 0 0 12118 0
N9K-M12PQ (Slot 2) in N9K-C9396 also seen on 40G interfaces on 9372PX switches.
Upgrade to a fixed release version of code, such as 7.0(3)I1(1) or newer
This is a non-impacting cosmetic issue. It is due to the port receiving packets where the actual number of bytes in the payload are not equal to type length field.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.