Loading...
Loading...
This issue can be observed just after removing the power supply physically. #show environment fex still incorrectly reports are power supply & fan status.
Incorrect reporting of the power supply & fan status with in #show environment fex on Nexus 7010 with NX-OS 6.2.6
None.
Verifying FEX-101 inventory within VDC=NSS:-------------------------------> D13-PT-7010-03-NSS# D13-PT-7010-03-NSS# !!!!!!!!! Power Supply-1 Removed !!!!!!!!!!!! D13-PT-7010-03-NSS# D13-PT-7010-03-NSS# D13-PT-7010-03-NSS# show environment fex 102 Temperature Fex 102: -------------------------------------------------------------------- Module Sensor MajorThresh MinorThres CurTemp Status (Celsius) (Celsius) (Celsius) -------------------------------------------------------------------- 1 Outlet-1 71 50 41 ok 1 Inlet-1 70 55 36 ok 1 Die-1 92 75 47 ok Fan Fex : 102: ------------------------------------------------------ Fan Model Hw Status ------------------------------------------------------ Chassis N2K-C2232-FAN -- ok PS-1 N2200-PAC-400W -- no power source <- Fan are working but shows incorrect information. PS-2 N2200-PAC-400W -- no power source Power Supply Fex 102: --------------------------------------------------------------------------- Voltage: 12 Volts ----------------------------------------------------- PS Model Power Power Status (Watts) (Amp) ----------------------------------------------------- 1 N2200-PAC-400W 396.00 33.00 ok <- Showing incorrectly the power supply-1 status as OK as power supply-1 is removed 2 N2200-PAC-400W 396.00 33.00 ok Mod Model Power Power Power Power Status Requested Requested Allocated Allocated (Watts) (Amp) (Watts) (Amp) --- ------------------- ------- ---------- --------- ---------- ---------- 1 N2K-C2232PP-10GE 144.00 12.00 144.00 12.00 powered-up Power Usage Summary: -------------------- Power Supply redundancy mode: redundant Total Power Capacity 792.00 W Power reserved for Supervisor(s) 144.00 W Power currently used by Modules 0.00 W ------------- Total Power Available 648.00 W ------------- D13-PT-7010-03-NSS# D13-PT-7010-03-NSS# Verifying FEX-102 inventory within VDC=CDS (default VDC):---------------------------> D13-PT-7010-03# D13-PT-7010-03# !!!!!!!! Power Supply-1 Inserted !!!!!!!!!!!! D13-PT-7010-03# D13-PT-7010-03# D13-PT-7010-03# show environment fex 101 Temperature Fex 101: -------------------------------------------------------------------- Module Sensor MajorThresh MinorThres CurTemp Status (Celsius) (Celsius) (Celsius) -------------------------------------------------------------------- 1 Outlet-1 63 45 36 ok 1 Inlet-1 65 55 37 ok 1 Die-1 100 85 47 ok Fan Fex : 101: ------------------------------------------------------ Fan Model Hw Status ------------------------------------------------------ Chassis N2K-C2248-FAN -- ok PS-1 N2200-PAC-400W -- no power source PS-2 N2200-PAC-400W -- no power source Power Supply Fex 101: --------------------------------------------------------------------------- Voltage: 12 Volts ----------------------------------------------------- PS Model Power Power Status (Watts) (Amp) ----------------------------------------------------- 1 N2200-PAC-400W -- -- fail/shutdown <- Showing inccorectly the power supply-1 status as fail as power supply-1 is inserted & working. 2 N2200-PAC-400W 396.00 33.00 ok Mod Model Power Power Power Power Status Requested Requested Allocated Allocated (Watts) (Amp) (Watts) (Amp) --- ------------------- ------- ---------- --------- ---------- ---------- 1 N2K-C2248TP-1GE 22.80 1.90 22.80 1.90 powered-up Power Usage Summary: -------------------- Power Supply redundancy mode: redundant Total Power Capacity 396.00 W Power reserved for Supervisor(s) 22.80 W Power currently used by Modules 0.00 W ------------- Total Power Available 373.20 W ------------- D13-PT-7010-03# D13-PT-7010-03#
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.