OPERATIONAL DEFECT DATABASE
...

...
CSCug95765: N7K-SUP2 : Low Output Reading on the N7K-AC-6.0KW PS Slot-2 in C7009
====== Low output on PS Slot2 in C7009 as following: Boxster# sh env power Power Supply: Voltage: 50 Volts Power Actual Total Supply Model Output Capacity Status (Watts ) (Watts ) ------- ------------------- ----------- ----------- -------------- 1 N7K-AC-6.0KW 1256 W 6000 W Ok 2 N7K-AC-6.0KW 14 W 6000 W Ok <<<<< This issue has no effects on the normal operation of N7K-AC-6.0KW PS Slot-2 and C7009.
======= N7K-SUP2 with PMFPGA version 36.
======== Upgrade N7K-SUP2 PMFPGA to version 37 or onwards. Resolution ======= The issue is resolved by upgrading N7K-SUP2 PMFPGA to version 37 or onwards.