Known affected version(s) that were inferred because the vendor did not provide any: 7.0.3.02300, 8.0.3.00100
In vSAN HCI with datastore sharing environment (formerly HCI Mesh), a vSAN datastore that belongs to one vSAN cluster can be mounted on hosts of other clusters. Such hosts provide only compute and not storage, and might not even have vSAN active. In the Site Recovery Manager reprotect workflow, if a certain API call is made to a host with no active vSAN, the call ends with a NotSupported exception. If such a call is made to a vSAN-enabled compute-only host, then you see no error, but the call does not return any results. This issue is resolved in this release. The fix makes sure API calls for the SRM reprotect workflow to pick up only hosts with active vSAN.
https://techdocs.broadcom.com/us/en/vmware-cis/vsphere/vsphere/7-0/release-notes/vcenter-server-update-and-patch-release-notes/vsphere-vcenter-server-70u3v-release-notes.html https://techdocs.broadcom.com/us/en/vmware-cis/vsphere/vsphere/8-0/release-notes/vcenter-server-update-and-patch-release-notes/vsphere-vcenter-server-80u3b-release-notes.html