A custom bug ID has been generated as the vendor did not provide one: 038dc1ebeb9e Known affected version(s) that were inferred because the vendor did not provide any: 8.0.1.00200
In the vSphere Client, when you create a new NFS3 datastore on an individual ESXi host and select the Bind to vmknic check box, you see a default bind target such as vmk0 . If you do not change the default, the task completes without an error, but port binding is not configured. The issue affects only the workflow for creating a new datastore in the vSphere Client for individual ESXi hosts, not for clusters. This issue is resolved in this release.