Android Tunnel shows 'No Managed Applications' even though present
SyncPerAppVpnAssociations command from DS to the device is missing the device UUID as in the log snippet where UUID is all zeros. This happens only compliance policy in place. XML to the device during the command: <cmd><id>63b379d3-0476-48f1-81e3-e3109802ffc0</id><type>150</type><parms><android_sync_per_app_vpn_associations_endpoint value="/devicesgateway/devices/00000000-0000-0000-0000-000000000000/device-perappvpn/associations" /></parms></cmd>
Newly enrolled device unable to access internal company resources as the per-app VPN is not getting connected.
This issue is fixed in UEM Console version 2306 and will be backported to 2302.
Workaround 1: Re-push the Per-App VPN profile to the affected device Workaround 2: Temporarily disable the compliance policy.