VxRail bundle does not show as available after NSX domain upgrade completed with success after previous failure attempts. Following logging is observed in lcm-debug.log file - 2022-03-16T19:08:19.166+0000 DEBUG [f1495dc4867f4408,191e] [c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] Filter available bundles from partnerSoftwareUpgrades for VXRAIL2022-03-16T19:08:19.234+0000 DEBUG [f1495dc4867f4408,191e][c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] NSX Bundle exists in all upgrade list which is yet to complete, nsx incomplete upgrade id=9c34c835-78aa-4e21-91e3-3e36df924ef42022-03-16T19:08:19.234+0000 DEBUG [f1495dc4867f4408,191e] [c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] NOT COMPLETED_WITH_SUCCESS NSX Bundle Id= 34bf8a15-1d99-4b28-a183-58bab2fa3f78 exists with upgrade id=9c34c835-78aa-4e21-91e3-3e36df924ef4, upgrade status= COMPLETED_WITH_FAILURE..2022-03-16T19:08:19.234+0000 DEBUG [f1495dc4867f4408,191e] [c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] NOT completed_WITH_SUCCESS NSX Domain ids= [83bac610-2c44-4f56-8132-f78db8dc11a9] for upgrade_id =5e265025-292a-4237-834c-1d9df4fef1392022-03-16T19:08:19.234+0000 DEBUG [f1495dc4867f4408,191e] [c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] partnerSoftwareUpgrades AvailableUpgrades =12022-03-16T19:08:19.234+0000 DEBUG [f1495dc4867f4408,191e] [c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] VxRail Bundle id =VXRAIL4-7-541-27403414DLD1227_VxRail-4-7-541-Composite-Upgrade-Package-for-4-7-x-zip, bundle type=VXRAIL2022-03-16T19:08:19.234+0000 DEBUG [f1495dc4867f4408,191e] [c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] vcenterIds =[dfe3e123-4762-4022-bada-60709066d2c5, 34df2b21-423d-400e-8b8b-55c498b520d3][c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] VxManager Bundle is available for domain with id = 83bac610-2c44-4f56-8132-f78db8dc11a92022-03-16T19:08:19.235+0000 DEBUG [f1495dc4867f4408,191e] [c.v.e.s.l.s.i.InventoryUpgradeServiceImpl,http-nio-127.0.0.1-7400-exec-11] Partner bundle domain id 83bac610-2c44-4f56-8132-f78db8dc11a9 exists in nsxtIncompleteDomainIDs so remove it from available upgrades Note: The above date and time will differ and is representational only
VxRail Bundle may not be available after upgrading the NSX-T successfully - Due to bundle cleanup during the NSX-T upgrade, entries deleted from upgrade table which causes vxRail bundle to unavailable.Entry for vxRail bundle previous version was missing in applicableForPartnerBundleVersions of PartnerBundleMetadata.json for target version
Fixed in VCF 3.11.1
Please contact VMware Support for a workaround solution
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.