vSphere Client "Updates" tab for the virtual machine shows both VMware Tools and VM Hardware Compatibility as "Unknown" for a virtual machine: Performing a scan operation using the "CHECK STATUS" option results in failure similar to the one shown below: The affected VM is configured for either of the following guest operating systems: Windows Server 2019Windows Server 2022Debian 11 (32 bit)Debian 11 (64 bit)Red Hat Enterprise Linux 9 (64 bit) In the VMware Update Manager server log (/var/log/vmware/vmware-updatemgr/server/vmware-vum-server-xx.log) you find the following entries: [#51] 2022-01-31T11:28:58.688+01:00 info vmware-vum-server[57005] [Originator@6876 sub=Activation.trace] [activationValidator 1127] Invoke done: integrity.UpdateManager.scan [#51] --> Result: [#51] --> 'vim.Task:c3513074-0f3f-4b7f-93ca-4d73ea63f475:task-298559' 2022-01-31T11:28:58.695+01:00 verbose vmware-vum-server[02327] [Originator@6876 sub=JobDispatcher] [JobDispatcher 420] The number of tasks: 1 2022-01-31T11:28:58.695+01:00 info vmware-vum-server[02327] [Originator@6876 sub=JobDispatcher] [JobDispatcher 2017] Scheduling task ScanTask{5326} 2022-01-31T11:28:58.695+01:00 info vmware-vum-server[02327] [Originator@6876 sub=JobDispatcher] [JobDispatcher 476] Starting task ScanTask{5326} 2022-01-31T11:28:58.695+01:00 info vmware-vum-server[02327] [Originator@6876 sub=VciScanTask.ScanTask{5326}] [vciTaskBase 1390] VciTask { id: ScanTask{5326}, type: com.vmware.vcIntegrity.ScanTask }: Setting VC task state to: running 2022-01-31T11:28:58.695+01:00 info vmware-vum-server[02254] [Originator@6876 sub=InventoryMonitor] [InventoryMonitor 517] ProcessUpdate, Enter, Update version := 1416 2022-01-31T11:28:58.695+01:00 info vmware-vum-server[02254] [Originator@6876 sub=InventoryMonitor] [InventoryMonitor 1675] UpdateHandler: Last updateSet 2022-01-31T11:28:58.695+01:00 verbose vmware-vum-server[57024] [Originator@6876 sub=JobDispatcher] [JobDispatcher 1700] ProcessUpdate 2022-01-31T11:28:58.700+01:00 info vmware-vum-server[57068] [Originator@6876 sub=VciScanTask.ScanTask{5326}] [vciTaskBase 579] Task started... 2022-01-31T11:28:58.700+01:00 info vmware-vum-server[57068] [Originator@6876 sub=InventoryTree] [InventoryTree 433] [AcquireWriteLock] Node vm-185497 write locked successfully, new Lock state: Write. 2022-01-31T11:28:58.700+01:00 info vmware-vum-server[57068] [Originator@6876 sub=entityLocker] [entityLocker 153] [LockEntitiesInt] Entities to be locked: 1, entities actually locked: 1 2022-01-31T11:28:58.706+01:00 warning vmware-vum-server[57068] [Originator@6876 sub=SessionMgr] [sessionMgr 104] Cannot get activation or session. Returning server locale 2022-01-31T11:28:58.713+01:00 error vmware-vum-server[57068] [Originator@6876 sub=vmOpsUtils] [vmOpsUtils 561] Action (SCAN) skipped for VM: <VM Name>. The guest OS Microsoft Windows Server 2022 (64-bit) is not supported 2022-01-31T11:28:58.716+01:00 info vmware-vum-server[57068] [Originator@6876 sub=InventoryTree] [InventoryTree 497] [ReleaseWriteLock] Released write lock on node vm-185497. Post unlock, notified all the waiting readers and writers. 2022-01-31T11:28:58.716+01:00 error vmware-vum-server[57068] [Originator@6876 sub=VciScanTask.ScanTask{5326}] [vciTaskBase 604] Task execution has failed: Fault cause: vmodl.fault.NotSupported Note: The preceding log excerpts are only examples. Date, time, and environmental variables may vary depending on your environment.
This issue occurs, because the specific operating system the virtual machine is configured with, is missing from the pre-populated list of OS versions supported by VMware Update Manager.
VMware is aware of this issue and working to resolve this in a future release.
As a workaround, you can manually add the operating system to the list for VMware Update Manager. To do this, please follow the steps below Connect to your vCenter Server Appliance per SSH and log inCreate a backup of the vci-integrity.xml file: mkdir /backup && cp /usr/lib/vmware-updatemgr/bin/vci-integrity.xml /backup/ Modify the vci-integrity.xml file by opening the file using vi editor: vi /usr/lib/vmware-updatemgr/bin/vci-integrity.xml Locate the <vci_vcIntegrity> ..... </vci_vcIntegrity> sectionEnter edit mode by hitting the insert or the letter i buttonBefore the </vci_vcIntegrity> line, add the following lines, depending on the operating system configured in your virtual machine. If entering both versions of the same OS (ie: Windows 2019 AND 2022), see the below Note section. For Windows Server 2019: <supportedWindowsGuestIds> <windows2019srv_64Guest/> </supportedWindowsGuestIds> For Windows Server 2022: <supportedWindowsGuestIds> <windows2019srvNext_64Guest/> </supportedWindowsGuestIds> For Debian 11 (32 bit): <supportedLinuxGuestIds> <debian11Guest/> </supportedLinuxGuestIds> For Debian 11 (64 bit): <supportedLinuxGuestIds> <debian11_64Guest/> </supportedLinuxGuestIds> For Red Hat Enterprise Linux 9 (64 bit): <supportedLinuxGuestIds> <rhel9_64Guest/> </supportedLinuxGuestIds> Note: if you would like to include both OS versions, you will need to combine the lines as seen below. For Windows <supportedWindowsGuestIds> <windows2019srv_64Guest/> <windows2019srvNext_64Guest/> </supportedWindowsGuestIds> For Debian <supportedLinuxGuestIds> <debian11Guest/> <debian11_64Guest/> </supportedLinuxGuestIds> Exit edit mode by hitting the ESC button Save and exit the file: :wq! Restart the VMware Update Manager service: # vmon-cli -r updatemgr
If the lines <supportedWindowsGuestIds> </supportedWindowsGuestIds> and/or <supportedLinuxGuestIs> </supportedLinuxGuestIds> appear more than once, VUM will crash.Ensure they appear only once in the file.---------------------------------------------------For Rocky Linux, use: <rocklinux_64Guest/> --------------------------------------------------- For Windows 11, use: <supportedWindowsGuestIds> <windows11_64Guest/> </supportedWindowsGuestIds>
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.