1. Unable to reconfigure VRMS post upgrade 2. hms-vpostgres service fails to start 2021-12-02 014.145 WARN com.mchange.v2.resourcepool.BasicResourcePool [C3P0PooledConnectionPoolManager[identityToken->z8kfltalxht64lh9k2oe|3301500b]-HelperThread-#17] (..log.slf4j.Slf4jMLog$Slf4jMLogger$WarnLogger) [] | com.mchange.v2.resourcepool.BasicResourcePool$ScatteredAcquireTask@7b787436 -- Acquisition Attempt Failed!!! Clearing pending acquires. While trying to acquire a needed new resource, we failed to succeed more than the maximum number of allowed acquisition attempts (30). Last acquisition attempt exception:org.postgresql.util.PSQLException: Connection to localhost:5432 refused. Check that the hostname and port are correct and that the postmaster is accepting TCP/IP connections.
Due to incorrect hostname in the /etc/hosts file.
NOTE: A normal snapshot must be taken before performing the steps mentioned here. SSH to the vSphere Replication appliance and run the commands below. 1. chmod 777 /var/log/vmware/vrmsdb/postgresql.log2. /opt/vmware/hms/bin/hms-configtool -cmd upgrade -configfile /opt/vmware/hms/conf/hms-configuration.xmlRunning this command will print the message below - 2021-12-02 14:22:53.679 INFO com.vmware.hms.configtool.App [main] (..hms.configtool.App) [] | HMS Configuration Tool 8.52021-12-02 14:22:53.711 INFO com.vmware.hms.configtool.App [main] (..hms.configtool.App) [] | FIPS mode: false2021-12-02 14:22:53.714 INFO com.vmware.hms.configtool.App [main] (..hms.configtool.App) [] | COMMAND: upgrade, CONFIG FILE: /opt/vmware/hms/conf/hms-configuration.xml2021-12-02 14:22:53.722 ERROR com.vmware.hms.configtool.App [main] (..hms.configtool.App) [] | Error while configuring HMS, exit code DATABASE_ERRORcom.vmware.hms.configtool.ConfigToolException: Unable to configure HMS: /tmp/hmsrpminfo (No such file or directory) at com.vmware.hms.configtool.App.setExitCode(App.java:353) ~[hms-configtool.jar:?] at com.vmware.hms.configtool.App.processXmlConfigFile(App.java:330) [hms-configtool.jar:?] at com.vmware.hms.configtool.App.go(App.java:242) [hms-configtool.jar:?] at com.vmware.hms.configtool.App.main(App.java:222) [hms-configtool.jar:?]Caused by: java.io.FileNotFoundException: /tmp/hmsrpminfo (No such file or directory) at java.io.FileInputStream.open0(Native Method) ~[?:1.8.0_301] at java.io.FileInputStream.open(FileInputStream.java:195) ~[?:1.8.0_301] at java.io.FileInputStream.<init>(FileInputStream.java:138) ~[?:1.8.0_301] at org.apache.commons.io.FileUtils.openInputStream(FileUtils.java:2387) ~[commons-io-2.10.0.jar:2.10.0] at org.apache.commons.io.FileUtils.readFileToString(FileUtils.java:2505) ~[commons-io-2.10.0.jar:2.10.0] at org.apache.commons.io.FileUtils.readFileToString(FileUtils.java:2488) ~[commons-io-2.10.0.jar:2.10.0] at com.vmware.hms.configtool.UpgradeProcessor.getPreviousHmsVersion(UpgradeProcessor.java:739) ~[hms-configtool.jar:?] at com.vmware.hms.configtool.UpgradeProcessor.upgrade(UpgradeProcessor.java:347) ~[hms-configtool.jar:?] at com.vmware.hms.configtool.Command$7.exec(Command.java:186) ~[hms-configtool.jar:?] at com.vmware.hms.configtool.App.processXmlConfigFile(App.java:314) ~[hms-configtool.jar:?] ... 2 moreUnable to configure HMS: /tmp/hmsrpminfo (No such file or directory)3. Reboot the appliance and reconfigure it.
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.