- CDO is enabled but showing failed status- Resync CDO does not help- Enable & Disable CDO also does not help.NSX logs show either or both of the following:2020-04-26 08:23:42.909 GMT ERROR TaskFrameworkExecutor-11 VdnCdoModeTask:153 - - [nsxv@6876 comp="nsx-manager" subcomp="manager"] Exception encountered in VDS dvs-xxxxcom.vmware.vshield.vsm.vdn.exceptions.XvsException: nullor2020-04-26 08:24:42.812 GMT ERROR TaskFrameworkExecutor-26 Worker:219 - - [nsxv@6876 comp="nsx-manager" subcomp="manager"] BaseException thrown while executing task instance taskinstance-2014451com.vmware.vshield.vsm.vdn.exceptions.XvsException: null at com.vmware.vshield.vsm.vdn.service.task.VdnCdoModeTask.run(VdnCdoModeTask.java:120) ~[vsphere-1.0.jar:?] at com.vmware.vshield.vsm.task.service.Worker.runtask(Worker.java:184) [vsm-core-1.0.jar:?] at com.vmware.vshield.vsm.task.service.Worker.executeAsync(Worker.java:122) [vsm-core-1.0.jar:?] at com.vmware.vshield.vsm.task.service.Worker.run(Worker.java:99) [vsm-core-1.0.jar:?] at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1149) [?:1.8.0_161] at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:624) [?:1.8.0_161] at java.lang.Thread.run(Thread.java:748) [?:1.8.0_161]
This is seen mostly when a host is not responsive, throws an error, or PSOD occurs.
Confirm that all hosts prepared for NSX are in a healthy, responsive, and connected state. Also, review host preparation and ensure all communication channels are up.
https://bugzilla.eng.vmware.com/show_bug.cgi?id=2173715
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.