OPERATIONAL DEFECT DATABASE
...

...
You see disk latency when using Jumbo Frames with iSCSI or NFS datastores.
The disk latency may happen if the storage processor or ESX/ESXi host is not configured properly for the MTU size which you selected.
To ensure the host is configured properly for the defined MTU size: Log in to ESX or ESXi host using SSH. For more information, see: Unable to connect to an ESX host using Secure Shell (SSH) (1003807) Tech Support Mode for Emergency Support (1003677) Using Tech Support Mode in ESXi 4.1 and ESXi 5.x (1017910) Run this command from the ESX/ESXi host:# vmkping -s MTU_header_size -d IP_address_of_NFS_or_iSCSI_server Where:-s sets the packet size-d indicates do not fragment the packet Note: Assuming header size = 216, then -s value (packet size) would be: 9000 - 216 = 8784Example command:# vmkping -s 8784 -d 192.168.1.100 If you receive a response, this means that the communication is occurring at a desired MTU. If you do not receive the response, run the vmkping command without -d option:# vmkping -s MTU_header_size IP_address_of_NFS_or_iSCSI_server If you receive a response, this means that the configuration issue still exists, but that the large packets are being fragmented. This issue may lead to disk latency, the disruption of networking or storage for other components in your environment. Fragmenting and re-assembling packets uses a lot of CPU resources on the switch, storage processor, and ESX hosts. Verify that the ESX/ESXi host is configured properly for Jumbo Frames. Run this command:# esxcfg-nics -lName PCI Driver Link Speed Duplex MAC Address MTU Descriptionvmnic0 0000:01:00.00 bnx2 Up 1000Mbps Full xx:xx:xx:xx:xx:xx 1500 Broadcom Corporation PowerEdge R710 BCM5709 Gigabit Ethernetvmnic1 0000:01:00.01 bnx2 Up 1000Mbps Full xx:xx:xx:xx:xx:xy 1500 Broadcom Corporation PowerEdge R710 BCM5709 Gigabit Ethernetvmnic2 0000:02:00.00 bnx2 Up 1000Mbps Full xx:xx:xx:xx:xx:xz 9000 Broadcom Corporation PowerEdge R710 BCM5709 Gigabit Ethernet Verify that the vSwitch is configured for Jumbo Frames once you find a value under the MTU column that matches your desired MTU size.# esxcfg-vswitch -lSwitch Name Num Ports Used Ports Configured Ports MTU UplinksvSwitch0 128 3 128 1500 vmnic0 PortGroup Name VLAN ID Used Ports Uplinks Management Network 0 1 vmnic0Switch Name Num Ports Used Ports Configured Ports MTU UplinksvSwitch1 128 2 128 1500 vmnic1 PortGroup Name VLAN ID Used Ports Uplinks VMnet VLAN 5 0 0 vmnic1Switch Name Num Ports Used Ports Configured Ports MTU UplinksvSwitch2 128 3 128 9000 vmnic2 PortGroup Name VLAN ID Used Ports Uplinks iSCSI_1 0 1 vmnic2 Verify the MTU column for the vSwitch that has the VMkernel port configured on it also matches the MTU size. For more information, see iSCSI and Jumbo Frames configuration on ESX/ESXi (1007654) or Enabling Jumbo Frames for VMkernel ports in a virtual distributed switch (1038827).Note: If the VMkernel or vSwitch are configured for Jumbo Frames, then there is a configuration problem either on a network component such as network switches or routers, or with the storage processor. Verify that all devices between the ESX host and the storage array (including physical network switches) are configured to support Jumbo Frames for the desired MTU size.
Using Tech Support Mode in ESXi 4.1, ESXi 5.x, and ESXi 6.xiSCSI または NFS データストアでジャンボ フレームを使用するときのディスク待ち時間のトラブルシューティング对将巨型帧与 iSCSI 或 NFS 数据存储一起使用时的磁盘滞后进行故障排除
Click on a version to see all relevant bugs
VMware Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.