During vSphere block mode export, in certain situations, it might be observed that the folders/objects get created in the storage bucket. However, the export job remains stuck, and the following error message is seen in the debug logs: "Open virtual disk file failed. The error code is 14009., try --help\nError: exit status 1" Veeam Kasten for Kubernetes requires network access from the cluster to vCenter and the ESX hosts in TKGs environments.
Verify Environmental Configuration Check firewall configuration - port 902 should be open between worker nodes to the ESX nodes.
In some cases, it may be observed that the data-mover pod does not initiate, and the log shows 14009 errors. Further troubleshooting to find why the data-mover is not initiating is recommended in these cases.