After either of the following scenarios, the Mine with Veeam dashboard is no longer listed in the Prism Element dropdown: Installing Nutanix Mine with Veeam on a Nutanix Cluster running AOS version 5.20.2. Upgrading a Nutanix Cluster with Nutanix Mine with Veeam already installed to AOS version 5.20.2.
To resolve this, do the following: Enable SSH on the Veeam Availability VM From the Prism "VM" dashboard, open a Nutanix Console to the Veeam Availability VM, and log in with the same user and password used for the web interface. Execute the following command to enable SSH sudo /etc/init.d/ssh start Connect to the Veeam Availability VM via SSH using Putty Copy the following command into a text editor and modify the highlighted portions entering the Prism Element's IP, cluster-admin login, and admin password.