The installation of the Veeam CDP I/O Filter fails during deployment with the following error: Error Installing VeeamCDP components on cluster: <clustername> ... Error: the operation is not allowed in the current state Error Failed to install VeeamCDP I/O filters: Failed to install VeeamCDP I/O filter on cluster: <clustername>
Veeam Support has determined that this issue is most frequently related to a network issue, either DNS resolution failure or neccesary ports were blocked.
DNS Resolution All servers involved in the I/O Filter installation (i.e., Veeam Backup Server, vCenter, and ESXi hosts) must be able to resolve each other via FQDN. Veeam Backup Server ↔ vCenter vCenter ↔ ESXi Host(s) ESXi Host(s) ↔ Veeam Backup Server Firewall Ports Ensure any firewall on or between the servers involved in the I/O Filter installation (i.e., Veeam Backup Server, vCenter, and ESXi hosts) have the necessary ports opened to allow communication. Required Ports for Backup Server Incoming Connections Required Ports for CDP Components
Other requirements can be found here: Veeam Backup & Replication User Guide > Continuous Data Protection (CDP) for VMware vSphere > Considerations and Limitations