Hotfix versions were inferred because the vendor did not list them explicitly: 10.2.10-h1, 10.2.10-h2, 10.2.10-h3, 10.2.10-h4, 10.2.10-h5, 10.2.10-h6, 10.2.10-h7, 10.2.10-h8, 10.2.10-h9, 10.2.10-h10, 10.2.10-h11, 10.2.10-h12, 10.2.10-h13, 10.2.10-h14, 10.2.10-h15, 10.2.10-h16, 10.2.10-h17, 10.2.10-h18, 10.2.10-h19, 10.2.10-h20, 10.2.10-h21, 10.2.10-h22, 10.2.10-h23, 10.2.10-h24, 10.2.10-h25, 10.2.10-h26
The earliest recollection of this bug is traced back to PAN-OS 10.2.10-h27 - July 15, 2026. This bug is fixed in PAN-OS versions 10.2.10-h27. ( PA-4000 and PA-5000 Series firewalls ) Fixed an issue where, when SSL decryption was enabled, you were unable to interact with the login button on some websites due to a content length mismatch error. This occurred because the firewall incorrectly flagged the final packet in the replay as send original when it contained only a gzip end marker and no data. For more information: https://docs.paloaltonetworks.com/pan-os/10-2/pan-os-release-notes/pan-os-10-2-10-known-and-addressed-issues/pan-os-10-2-10-h27-addressed-issues