Operational Defect Database

BugZero updated this defect 21 days ago.

Palo Alto Networks | PAN-148971

If you enter a search term for Events that are related to IoT in the System logs and apply the filter, the page displays an Invalid term error. Workaround: Specify iot as the Type Attribute to filter the logs and use the search term as the Description Attribute . For example: ( subtype eq iot ) and ( description contains 'gRPC connection' ) .

Last update date:

7/2/2024

Affected products:

Pan OS

Affected releases:

10.1.9

10.1.4

10.1.14

Fixed releases:

No fixed releases provided.

Description:

The earliest recollection of this bug is traced back to PAN-OS 10.1.14 - July 02, 2024. If you enter a search term for Events that are related to IoT in the System logs and apply the filter, the page displays an Invalid term error. Workaround: Specify iot as the Type Attribute to filter the logs and use the search term as the Description Attribute . For example: ( subtype eq iot ) and ( description contains 'gRPC connection' ) . For more information: https://docs.paloaltonetworks.com/pan-os/10-1/pan-os-release-notes/pan-os-10-1-14-known-and-addressed-issues/pan-os-10-1-14-known-issues https://docs.paloaltonetworks.com/pan-os/10-1/pan-os-release-notes/pan-os-10-1-4-known-and-addressed-issues/pan-os-10-1-4-known-issues https://docs.paloaltonetworks.com/pan-os/10-1/pan-os-release-notes/pan-os-10-1-9-known-and-addressed-issues/pan-os-10-1-9-known-issues

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Known

Learn More

Search:

...