On an HPE HyperConverged (HC) 380 configured with OneView Instant On (OVIO)Version 1.3.1.8, OVIO fails in the vCenter configuration with an "Unknown Cluster Deployment Status" posted to the right of the "Destination Cluster" drop down.
This issue occurs when there is one or more properly formed deployment XML files located in the InstantOn\config\<HC380 Cluster name: HMD-HC380-ClusterVM_IDC-OF>. As a result, a copy of "deployment1.xml" called "deployment1 - Copy.xml" will be found in the "OneView InstantOn" wizard.
The following result of the presence of these two XML files will be shown:
The VMware_ex_?.log file posts ""2016/10/12 11:03:15.091", 5 (VCenter Validation), INFORMATION, Unusable cluster HMD-HC380-ClusterVM (IDC-OF) found 6 vs 3."
Scope
Any HPE HyperConverged (HC) 380 configured with OneView Instant On (OVIO) Version 1.3.1.8.
Resolution
Remove all the files except for the XML files related to this deployment:
On the hpe-hc-mgmt, log on as:
Administrator
<Password>
Locate the folder and change the directory to:
c:\ProgramData\Hewlett-Packard\StoreVirtual\InstantOn\config\ <HC380 Clsuter name: HMD-HC380-ClusterVM_IDC-OF>
Backup this folder to:
c:\ProgramData\Hewlett-Packard\StoreVirtual\InstantOn\config\backup
Remove all the files in this folder except for the "deployment.xml"
NOTE: There will be more than one XML file if this deployment was expanded.
RECEIVE PROACTIVE UPDATES
: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:
Proactive Updates Subscription Form.
NAVIGATION TIP
: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the
Navigation Tips document
.
SEARCH TIP
: For hints on locating similar documents on HPE.com, refer to the
Search Tips document
.