The HPE Hyper Converged 250 for Microsoft Cloud Platform System Standard requires specific server boot options (iLO4 configuration, power management, boot mode), registry setting (bus type), OS power configuration, and network adapter settings (VMQ, buffer size) for successful system deployment and runtime operation.Using the server default boot options or changing the factory set boot options associated with iLO4 configuration, power management, or boot mode may cause the HPE Hyper Converged 250 for Microsoft Cloud Platform System Standard to behave unpredictably during deployment and runtime. Symptoms of incorrect boot options include, but are not limited to, degraded hardware alerts, a hung boot process, and issues with system management connectivity.NOTE: The server default settings can be found in theHPE UEFI System Utilities User Guide for HPE ProLiant Gen9 Servers.Updating Smart Array drivers with the HPE Service Pack for ProLiant (SPP) resets the factory programmed Smart Array registry value for bus type to the server default value. Once a node is rebooted with this registry value, the HPE StoreVirtual VSA on that node will not start and the failure appears as a failed node in the HPE StoreVirtual Centralized Management Console (CMC). If multiple nodes are rebooted, the VSA may also lose quorum, causing data to become unavailableNOTE: Systems received prior to 1 April 2016 may have one or more of these boot options incorrectly programmed at the factory.The required boot options, now programmed at the factory, are as follows:iLO 4 configuration - Network Interface Adapter =ONPower Management - Power Profile =Maximum PerformanceBoot Options - Boot Mode =UEFI ModeThe required Smart Array registry setting:8The OS power configuration should be set to8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c.Specific node network adapter settings are also required for acceptable performance. These settings include:Disabled Virtual Machine Queue (VMQ)Receive buffer size = 2048
These boot options, registry settings, and OS power configuration and network adapter settings pertain to the HPE Hyper Converged 250 for Microsoft Cloud Platform System Standard.Verify current boot options using the HPE UEFI System Utilities.To verify the BusType registry value, log into the node through iLO or using the administrator password set during solution deployment. From the command prompt, run the following command (without line breaks):reg query HKLM\System\CurrentControlSet\Services\HpCISSs3\ParametersIf the returned BusType value, as shown in the yellow box below, is not 8, the value must be changed.To verify the OS power configuration and network settings, open a Windows PowerShell session from the Console VM as an administrator.Issue the following command on a single line to display the current OS power configuration setting:powercfg /getactiveschemeIssue the following command on a single line for VMQ status:Get-netadaptervmqIssue the following command on a single line for the receive buffer size:Get-NetAdapterAdvancedProperty -DisplayName 'Receive Buffers'
All setting changes should be made at one time to a single node. Once the updates are complete and the node is operational, update the next node.Boot OptionsUse the HPE UEFI System Utilities to verify and change the iLO4 Configuration and Power Management boot options on each node. See theHPE UEFI System Utilities User Guide for HPE ProLiant Gen9 Serversfor specific instructions.NOTE: You will need to validate and/or change the settings on each node of the system. For example, if you have a system with four nodes, you will need to perform this procedure four times.NOTE: If one or more of these settings need to be updated on a node, the node must be rebooted one or more times. See theHPE Hyper Converged 250 for Microsoft Cloud Platform System Standard User Guidefor additional considerations when powering a system off and on.Verifying or changing these settings requires direct connection to the node’s Keyboard/Video/Monitor (KVM) port or an iLO remote console session to the node.Once you have established a connection and logged into to the node:Power on, or restart the node.During startup, pressF9when prompted to enter theSystem Utilities.Change the iLO 4 Network Option:From theSystem Utilitiesscreen, selectSystem Configuration-iLO 4 Configuration Utility-Network Optionsand pressEnter.SelectNetwork Interface Adapterand pressEnter.SelectONand pressEnter.PressF10.Reboot the node.During startup, pressF9when prompted to enter theSystem Utilities.Change the Power Profile and Power Regulator settings:From theSystem Utilitiesscreen, selectSystem Configuration-BIOS/Platform Configuration (RBSU)-Power Management-Power Profileand pressEnter.SelectMaximum Performanceand pressEnter.PressF10.Reboot the node.Allow the node to reboot and continue with deployment or normal operations.Smart Array Registry SettingIMPORTANT: To avoid disruption to I/O on deployed solutions, complete the entire procedure on one node and confirm that the HPE StoreVirtual storage cluster is operational before starting on the next node. The HPE StoreVirtual storage cluster can be monitored using the HPE StoreVirtual CMC.CHANGING THE REGISTRY SETTINGUse the procedure below to manually update the Smart Array registry setting on a node:Connect to the node being updated through iLO or the optional SUV cable.2. Log in to the node using the administrator password set during solution deployment.3. At the command prompt, update the registry value with the following command (without line breaks):reg add HKLM\System\CurrentControlSet\Services\HpCISSs3\Parameters /v BusType /D 8 /FWait for the message indicating the operation succeeded.Confirm the registry value with the following command (without line breaks)reg query HKLM\System\CurrentControlSet\Services\HpCISSs3\ParametersConfirm that the Value for BusType is 8:Reboot the node with theshutdown /r /t 0command.NOTE: The reboot may take up to 40 minutes to complete on nodes running image version 1.0.0.39.RECOVERING THE VSA AFTER CHANGING THE REGISTRY SETTINGAfter changing the registry settings on your deployed HPE Hyper Converged 250 for Microsoft Cloud Platform System Standard solution, use the following steps to restore your system to normal operation.From the Start menu in the Console Virtual Machine, start theHyper-V Manager.SelectConnect to Serverand provide the host OS node name for the node whose registry settings were just changed. Once connected, you should see the HPE StoreVirtual VSA in a powered off state.Right-click the powered off HPE StoreVirtual VSA and selectSettings.ExpandSCSI Controllerin the left-hand navigation tree.UnderSCSI Controller, selectHard Drive.In the right-hand pane underPhysical hard disk:, from the drop down menu, select the drive previously presented to the HPE StoreVirtual VSA; the largest capacity drive in the list. This reallocates that drive to the VSA:If the solution also contains SSDs, repeat step 6 and select the SSD. SSD options appear in the list with a capacity of 400 GB only:ClickOKto save the changes.Right-click the powered off HPE StoreVirtual VSA, and selectStartto power it on.Verify that the state of the VSA changes from "off" to "on."Using the CMC, verify that the HPE StoreVirtual VSA is active.Expand the left-hand navigation tree under the recovered HPE StoreVirtual VSA.SelectStorage.Select theDisk Setuptab and verify the Status as "Active" and the health as "Normal."Close the Hyper-V Manager and CMC. The solution is now operational.OS Power Configuration and Network Adapter SettingsAs an administrator, open a Windows PowerShell session from the Console VM to verify and update OS power configuration and a node’s network adapter VMQ and receive buffer size settings.To set the OS power configuration setting, issue the following command on a single line:powercfg -setactive 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635cTo disable VMQ, issue the following command on a single line:Get-NetAdapter -InterfaceDescription *10Gb* | disable-netadaptervmqTo increase the receive buffer size, issue the following command on a single line:Get-NetAdapter -InterfaceDescription *10Gb* | Set-NetAdapterAdvancedProperty -DisplayName 'Receive Buffers' -DisplayValue 2048RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.