On an HPE ProLiant server with a network device, when the amount of MSI-X interrupts exceeds the limit in Red Hat Enterprise Linux 5 or Red Hat Enterprise Linux 6.6 (or earlier), a panic may be observed as follows:Feb 21 13:00:29 system01 kernel: bnx2x: [bnx2x_sp_post:3380(piv1)]BUG!EQ ring full!Feb 21 13:00:29 system01 kernel: bnx2x: [bnx2x_sp_post:3382(piv1)]driver assertFeb 21 13:00:29 system01 kernel: bnx2x: [bnx2x_panic_dump:719(piv1)]begin crash dump -----------------Feb 21 13:00:29 system01 kernel: bnx2x: [bnx2x_panic_dump:725(piv1)]def_idx(0x93b5) def_att_idx(0x144e) attn_state(0x0) spq_prod_idx(0xac)next_stats_cnt(0x94a5)
Any HPE ProLiant Server running Red Hat Enterprise Linux 5 or Red Hat Enterprise Linux 6.6 (or earlier).
This does not occur with Red Hat Enterprise Linux 6.7 (or later).Verify that MSI-X is in use for ALL of the network devices. This includes the network port physical device and configured bonds. If any of them are reporting MSI and MSI-X in /proc/interrupts, a panic may occur.To avoid the panic, decrease the MSI-X hardware interrupt usage that is limited and hard coded in Red Hat Enterprise Linux 5. Decrease the amount of bonded configurations and disable any network port that is not used in the system BIOS.The limited amount of MSI-X interrupts is by design in Red Hat Enterprise Linux. Reference the Red Hat Enterprise Linux documentation for more information on MSI-X interrupts, located at the following Red Hat website:www.redhat.comRECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HPE.com, refer to theSearch Tips document.To search for additional advisories related to Red Hat Enterprise Linux 5, use the following search string:+Advisory +ProLiant -"Software and Drivers" +Red Hat Enterprise Linux 5
Operating Systems Affected:Linux - Enterprise Red Hat 5
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.