Loading...
Loading...
An issue has been seen where an HP P2000 G3 MSA Array Controller may crash with the following 107 Critical Error Message:B1288 2015-08-03 16:11:49 107 ERROR Critical Error: Fault Type: Page Fault p1: 0x0192857, p2: 0x0194ACB, p3: 0x0194F10, p4: 0x0183F55 CThr: FOMThread, p2: 0x01924F3, p3: 0x0192938, p4: 0x0181B21 CThr: FOMThread
HP P2000 G3 MSA Array Systems are affected by this issue.
If the HP P2000 G3 MSA array is on a firmware version earlier than TS251P004-02, a reboot of both controllers will get the system stable so that the firmware on the array can be upgraded. There have been fixes and debug print enhancements added into new firmware for this issue. If the array is on TS251P004-02 or any firmware later than TS251P004-02, gather logs from both controllers and elevate a case to the MSA Engineering Resolution Team (ERT). Do not replace any hardware until requested to do so by MSA ERT.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.