An HP ProLiant m710p server is unable to execute Kdump when the server is running Red Hat Enterprise Linux (RHEL)6.7 on a Samsung PM953 960 GB M.2 drive.When the Kdump process is executed, the vmcore file is not generated as expected. The vmcore provides the information needed to debug.Note: This issue occurs because the RHEL 6.7 2.6 Kernel does not support nvme devices.
Any ProLiant m710p server configured with a Samsung PM953 960 GB M.2 drive and running RHEL 6.7.
RHEL 7.2 is the minimum RHEL version supported for the ProLiant m710p, and does not experience the Kdump issue.If the drive stated above must be used, perform either of the following:Upgrade the OS to RHEL 7.2.ORUpgrade the RHEL 6.7 kernel to 3.0This advisory will be updated when additional solutions become available.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.
Operating Systems Affected:Not Applicable