As larger-capacity drives (such as the 6TB MDL SAS hard drive) are introduced to the HP P2000 G3 MSA array, the size limit of the virtual disk (Vdisk) must be considered when creating a Vdisk with the large-capacity drives.In both theHP P2000 G3 MSA System SMU Reference GuideandHP P2000 G3 MSA System CLI Reference Guide, the minimum and maximum number of disks supported for specific RAID levels are defined as follows:NRAID: 1 diskRAID 0: minimum of 2 disks to maximum of 16 disksRAID 1: minimum of 2 disks to maximum of 2 disksRAID 3: minimum of 3 disks to maximum of 16 disksRAID 5: minimum of 3 disks to maximum of 16 disksRAID 6: minimum of 4 disks to maximum of 16 disksRAID 10: minimum of 4 disks to maximum of 16 disksRAID 50: minimum of 6 disks to maximum of 32 disksThe maximum numbers should be adjusted to account for the larger-capacity drives.
This issue affects HP P2000 G3 MSA Array Systems.
While creating a Vdisk with large-capacity drives, the maximum number of disks supported in a Vdisk should be adjusted as below, depending on the RAID level and the drive capacity (there is no change of maximum disks for RAID level NRAID, RAID1, and RAID10). The largest drive validated for the HP P2000 G3 MSA array is the 6TB drive.Raid levelMinimum disksMaximum disks6TB drive4TB drive3TB drive2TB or less driveRAID0210161616RAID3311161616RAID5311161616RAID6412161616RAID50612182232