Document VersionRelease DateDetails307/19/2016Updated the Resolution to indicate the HP Firmware Flash for Emulex Converged Network Adapters Version 2015.06.01 (15 Jun 2015) is removed.211/04/2015Updated the Resolution with the permanent fix.109/23/2015Original Document Release.HP ProLiant BL460c Gen9 and ProLiant BL660c Gen9 server blades configured with the System ROM Version 1.50 and HP FlexFabric 20Gb 2-port 650M/650FLB Network Adapters Firmware Version 10.5.65.21 will experience a Red Screen or Non-Maskable Interrupt (NMI) error at the end of the Power-On Self Test (POST). The server will not be able to boot into an operating system. This will occur only with this combination of the System ROM and firmware version of the network adapters.
Any HP ProLiant BL460c G9 or HP ProLiant BL660c Gen9 Server Blade running System ROM Version 1.50 and configured with HP FlexFabric 20Gb 2-port 650M or FlexFabric 20Gb 2-port 650FLB Network Adapters Firmware Version 10.5.65.21.
This issue is corrected by upgrading to System ROM Version 1.52 or Version 2.20:Click on the following URL:http://h20566.www2.hpe.com/portal/site/hpscEnter a product name (e.g., such as "HP ProLiant BL460c Gen9") in the text field under Enter a Product Name or Number and clickGo.Click the "drivers, software & firmware" hyperlink under the Download Options tab.Select the appropriate product model from the "Results from all HPE products" listed under the From all products tab on the Select an HPE product page.Select the appropriate operating system.Select the category "BIOS - System ROM."Select the version of the System ROM and click "Download."NOTE: Version 10.5.65.21 of the NIC Firmware isNO LONGER AVAILABLEfor download due to this issue. The package has been removed due to an incompatibility between System ROM Version 1.50 on HPE ProLiant BL460c Gen9 and BL660c Gen9 servers and with firmware version 10.5.65.21 on the HPE FlexFabric 650M and 650FLB Converged Network Adapters.As a workaround, move the affected NIC adapters to a different server to reinstall the NIC firmware.The following information will apply whether the firmware flash operation is run on a running operating system or if HP Smart Update Manager (HP SUM) offline is used.To move the affected NICs to a different server:Select a server running an older version of the System ROM, such as the System ROM from Service Pack for ProLiant 2015.10.02.Perform the hardware changes necessary to place the cards in the second server temporarily.Update the firmware on the NICs using the instructions below.Reinstalling the NIC FirmwareAssuming the System ROM is downgraded and/or the NICs have been moved to a different server running the earlier System ROM, flash the NICs using online using a running operating system or offline HP SUM.Running operating system:Apply the appropriate component listed below to update the firmware on the affected NICs to firmware version 10.5.160.0 (10.5.65.25 for VMware 5.1 systems).Update the running operating system with the Emulex FC/FCoE and NIC drivers from Service Pack for ProLiant 2015.10.02 and reboot.Deploy the appropriate firmware flash component to the target system from HP SUM (downloadable from hp.com) or launch the component at the operating system level. See the links below Step 4.If the NICs are moved to a different system, move them back to the original system now.Reboot as usual.Windows 64-Bit:http://www.hp.com/swpublishing/MTX-91210271b8e7497784f7b8a0f1Linux 64-bit:http://www.hp.com/swpublishing/MTX-664b7076fa794d5098d42afa7eVMware 5.1:https://downloads.hpe.com/pub/softlib2/software1/sc-linux-fw-sys/p930408510/v112197/CP027843.zipVMware 5.5/6.0:http://www.hp.com/swpublishing/MTX-b23059f1b3b24390a33b535364Build an Offline Customized SPP ISO By Using an HP SUM Custom ISO Feature:Build a bootable copy of customized ISO and include the Linux 64-bit firmware component (above). If necessary, see the HP SUM documentation for instructions.Boot the affected server into offline custom ISO, and allow the firmware on the NIC cards to be updated.Upon reboot, install the latest FC/FCoE and NIC drivers for your NICs using Service Pack for ProLiant 2015.10.02.NOTE: These components will be included in an upcoming release of Service Pack for ProLiant.If Firmware Version 10.5.160.0 (10.5.65.25 for VMware 5.1 systems) cannot be installed on the FlexFabric 20Gb 2-port 650M/650FLB adapters immediately, use the firmware from Service Pack for ProLiant 2015.04.0 (version 10.2.477.23) to downgrade the adapters, since the earlier firmware version will not exhibit this issue. Follow the process outlined above to load the earlier NIC firmware components.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.