With the release of firmware versions GL210R004 and TS252R007, the HP MSA 2040, MSA 1040, and P2000 G3 MSA Arrays need to have HTTPs enabled for Remote Replication to work correctly. This action was taken to ensure replication communication between the arrays function on a secure protocol communication. If a customer had previously configured Remote Replication using HTTP only, the replication would resume once HTTPs is enabled.Customers can still use HTTP for regular System Management Utility (SMU) access. Both HTTP and HTTPs can be enabled at the same time. For greater security, customers should only use HTTPs and disable HTTP.
The following products are affected by this issue:HP MSA 2040 SAN StorageHP MSA 1040 SAN StorageHP P2000 G3 MSA Array Systems
For replication communication to complete successfully, enable HTTPs using either the SMU or CLI/telnet.To enable HTTPs using SMU v3:Using either of the following:In the banner, click the system panel and selectSet Up System Services.In the System topic, selectAction→Set Up System Services.ClickOKto enable HTTPs.To enable HTTPs using SMU v2 (applies to the P2000 also):SelectConfiguration→Services→Management.ClickApplyto enable HTTPs.If the SMU is configured to use HTTPs, ensure that Internet Explorer is set to use SSL 3.0 and either TLS 1.1 or TLS 1.2.To enable HTTPs using CLI/telnet:Enter# set protocols HTTPs enabled.