Document VersionRelease DateDetails207/09/2015Updated the Resolution with release information for HP OneView for Microsoft System Center 7.6 that will permanently fix this issue.101/12/2015Original Document Release.On System Center Configuration Manger (SCCM) 2012 R2 with Cumulative Update 2 or later, the hpproliantsccmkit-install.ps1 PowerShell installer script will display an exception when the following driver packages are installed: Windows 2008 R2 x64 Driver Package, Windows 2012 x64 Driver Package, or Windows 2012 R2 x64 Driver Package. In addition:The following PowerShell exception may also be seen when calling get-cmdriver, Get-cmcategory cmdlets.TheNew-cmdriverpackagecmdlet will no longer recognize the PackageSourceType parameter and the Import-cmdriver fails with an invalid object path.This is due to the changes in Microsoft PowerShell cmdlets behavior after applying SCCM 2012 R2 Cumulative Update 2 (or later).
Any HP ProLiant server upgraded with SCCM 2012 R2 Cumulative Update 2 or Cumulative Update 3 when System Center Configuration Manager (SCCM) 2012 Integration Kit Version 2014.02.0 (or later) is installed.
Download and install the HP OneView for Microsoft System Center 7.6 release to correct this issue:https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=System_CenterAs a workaround, reinstall the HP SCCM 2012 Kit. Please read this entire section first before proceeding with the actual steps. These instructions are not intended for upgrading.<SCCM Root> represents the root directory of the SCCM installation, e.g., C:\Program Files\Microsoft Configuration Manager.<SCCM Console Root> represents the root directory of the SCCM console installation, e.g., C:\Program Files (x86)\Microsoft Configuration Manager.Before beginning, ensure the following:You have local administrator privilegesSCCM 2012 R2 or later is installedThis is the SCCM primary site server with consoleCAUTION: This document contains information about how to modify the registry. Use the Registry Editor at your own risk! The registry should be backed up before modifying it. If the Registry Editor is used incorrectly, serious issues could occur that may require a reinstallation of the operating system. For more information about how to back up, restore, and modify the registry, see Microsoft Knowledge Base Article 256986, titled Windows registry information for advanced users.Click here to view Microsoft Knowledge Base Article 256986:http://support.microsoft.com/kb/256986/Steps to Reinstall:Open the SCCM console.Delete the following HP objects:Application Management-> Packages->HP ProLiant Inventory ToolOperating Systems-> Driver Packages->HP ProLiant Windows 2008 R2 x64 Driver PackageOperating Systems->Driver Packages->HP ProLiant Windows 2012 x64 Driver PackageOperating Systems->Driver Packages ->HP ProLiant Windows 2012 R2 x64 Driver PackageOperating Systems->Drivers, delete all drivers that have a category starting with "HP ProLiant�", e.g., "HP ProLiant Networking" or "HP ProLiant Storage."Close the console.Delete the following HP folders:<SCCM Root>\OSD\Lib\DriverPackages\HP\ProLiant<SCCM Root>\OSD\Lib\Drivers\HP\ProLiant<SCCM Root>\OSD\Lib\Packages\HP\ProLiant<SCCM Root>\OSD\LibDelete the following HP files:<SCCM Root>hpproliantsccm2012kit-uninstall.exeDelete the following HP registry keys:HKLM\SOFTWARE\Microsoft\SMS\HP\ProLiantDelete the following HP hardware inventory classes from SCCM Console:HW Inventory agent setting >Hardware inventory classes > Set Classes� delete the following classes/class settings:HP ProLiant Location (HP_ProLiantLocation)HP ProLiant System Summary (HP_ProLiantSystemSummary)HP ProLiant Version Control (HP_ProLiantVersionControl)Extract the hpsccm2012kit-2014.##.#.##.exe installer kit.Create a folder" <SCCM Root>\OSD\Lib\" and copy "drivers" folder from the extracted installer source into "<SCCM Root>\>\OSD\Lib\".Create a folder "<SCCM Root>\OSD\Lib\Packages\HP\ProLiant\" and copy "inventorytool" folder from the extracted installer source into "<SCCM Root>\OSD\Lib\Packages\HP\ProLiant\".Create the following driver package folders:<SCCM Root>\OSD\Lib\DriverPackages\HP\ProLiant\HP ProLiant Windows 2008 R2 x64 Driver Package<SCCM Root>\OSD\Lib\DriverPackages\HP\ProLiant\HP ProLiant Windows 2012 x64 Driver Package<SCCM Root>\OSD\Lib\DriverPackages\HP\ProLiant\HP ProLiant Windows 2012 R2 x64 Driver PackageStart the Software Library->Operating Systems ->Driver Packages Create Driver Package wizard. Specify the following values:Name = HP ProLiant Windows 2008 R2 x64 Driver PackagePath = \\<Server UNC>\SMS_<Site Code>\OSD\Lib\DriverPackages\HP\ProLiant\HP ProLiant Windows 2008 R2 x64 Driver PackageOpen the properties of the new driver package and specify the following:Data Access tab: Select Copy the content in this package to a package share on distribution pointsStart the Software Library->Operating Systems ->Driver Packages Create Driver Package wizard. Specify the following values:Name = HP ProLiant Windows 2012 x64 Driver PackagePath = \\<Server UNC>\SMS_<Site Code>\OSD\Lib\DriverPackages\HP\ProLiant\HP ProLiant Windows 2012 x64 Driver PackageOpen the properties of the new driver package and specify the following:Data Access tab: Select "Copy the content" in this package to a package share on distribution pointsStart the Software Library -> Operating Systems-> Driver Packages Create Driver Package wizard. Specify the following values:Name = HP ProLiant Windows 2012 R2 x64 Driver PackagePath = \\<Server UNC>\SMS_<Site Code>\OSD\Lib\DriverPackages\HP\ProLiant\HP ProLiant Windows 2012 R2 x64 Driver PackageOpen the properties of the new driver package and specify the following:Data Access tab: Select "Copy the content" in this package to a package share on distribution pointsStart the Software Library->Operating Systems-> Drivers Import Drivers wizard. Specify the following values:On the Locate Driver step:Import all drivers in the following network path (UNC)Source folder = \\<Server UNC>\SMS_<Site Code>\OSD\Lib\drivers\ws2008r2-x64Specify the option for duplicate drivers = Import the driver and keep existing categoriesOn the Driver Details step:Import drivers will be listed."Enable these driver and allow computers to install them" leave as-is by default."Assign this driver to one or more categories for filtering," select "Categories" button and create a category name as "HP ProLiant WS2008R2 x64."On the Add Driver to Packages step, select HP ProLiant Windows 2008 R2 x64 Driver Package.On the Add Driver to Boot Image step, do not select anything.ClickNextfor import drivers.Start the Software Library ->Operating Systems ->Drivers Import Drivers wizard. Specify the following values:On the Locate Driver step:Import all drivers in the following network path (UNC)Source folder = \\<Server UNC>\SMS_<Site Code>\OSD\Lib\drivers\ws2012-x64Specify the option for duplicate drivers = Import the driver and keep existing categoriesOn the Driver Details step:Import drivers will be listed."Enable these driver and allow computers to install them" leave as-is by default."Assign this driver to one or more categories for filtering" select "Categories" button and create category names as"HP ProLiant WinPE 4.0 x64"and"HP ProLiant WS2012 x64."On the Add Driver to Packages step, select HP ProLiant Windows 2012 x64 Driver Package.On the Add Driver to Boot Image step, do not select anything.ClickNextto import drivers.Start the Software Library->Operating Systems->Drivers Import Drivers wizard. Specify the following values:On the Locate Driver step:Import all drivers in the following network path (UNC)Source folder = \\<Server UNC>\SMS_<Site Code>\OSD\Lib\drivers\ws2012r2-x64Specify the option for duplicate drivers = Import the driver and keep existing categoriesb. On the Driver Details step:Import drivers will be listed."Enable these driver and allow computers to install them" leave as-is by default."Assign this driver to one or more categories for filtering," click "Categories" button and create category names as "HP ProLiant WinPE 5.0 x64" and "HP ProLiant WS2012R2 x64."On the Add Driver to Packages step, select HP ProLiant Windows 2012 R2 x64 Driver Package.On the Add Driver to Boot Image step, do not select anything.ClickNextto import drivers.Start the Software Library->Application Management->Packages Create Package wizard. Specify the following values:Name = HP ProLiant Inventory ToolSelect "This package contains source files"Source folder = \\<Server UNC>\SMS_<Site Code>\OSD\Lib\packages\HP\ProLiant\inventorytoolStandard programName = HP ProLiant Inventory ToolCommand line = hpproliantinvtool.exeProgram can run = Whether or not a user is logged onOpen the properties of the new package and specify the following:Data Access tab: Select "Copy the content in this package to a package share on distribution points"Create the following HP registry key and values:Open Windows Registry Editor. From Windows Start menus, selectRunand enter regedit in theOpentextbox.ClickBrowse.Expand: HKLM\SOFTWARE\Microsoft\SMS\HP\ProLiantOn the Edit menu, clickNew Value.Add the registry key values.Note: All values are string:Name = HP ProLiant SCCM 2012 Integration KitVersion = ####.##.#.##Where ####.##.#.## is the installer product version which can be located by right click on installer kit propertiesClick on Details view.From the File menu, clickExitto close Windows Registry Editor.After the kit is re-installed, the remaining operation should function. Refer to the following guide to complete the rest of the configuration steps:HP SCCM 2012 Integration Kit User GuideDisclaimer:Note: One or more of the links above will take you outside the Hewlett-Packard web site. HP does not control and is not responsible for information outside of the HP web site.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription FormNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.