IMPORTANT: The HP Smart Array Controller firmware upgrade described in the Resolution is considered a critical fix and is required to prevent erroneous SATA hard drive failures from occurring. HP strongly recommends immediate application of this critical fix. Neglecting to perform the required action could leave the server in an unstable condition, which could potentially result in sub-optimal server performance, server lock-ups or failures, or ungraceful server shutdowns. By disregarding this notification and not performing the recommended resolution, the customer accepts the risk of incurring future related errors.On the HP ProLiant Gen9 servers listed under Platforms Affected configured with an HP Smart Array P441 Controller or HP H241 Smart Host Bus Adapter (HBA) running Firmware Version 1.14 - 1.18, configured for RAID, and attached to an HP D3600 or D3700 Enclosure, SATA drives configured in Bay 1 and/or Bay 2 may be erroneously marked as failed, leading to the LUNs entering interim recovery mode after a reboot.When this occurs, drives in Bay 1 are more likely to encounter this issue, but this may occur in either or both drive bays.
Any HP ProLiant Gen9 server listed under Platforms Affected configured with an HP Smart Array P441 Controller or HP H241 Smart HBA running Firmware Version 1.14 - 1.18, configured for RAID, and connected to an HP D3600 or D3700 Enclosure.
To ensure that SATA drives configured in Bay 1 and/or Bay 2 are not erroneously marked as failed, upgrade to HP Smart Array Controller Firmware Version 1.34 (B) or later, which can be located using the following navigation:Go tohttp://www8.hp.com/us/en/drivers.htmlEnter the Smart Array Controller model (for example, "Smart Array P441") and clickSearch.Select the appropriate operating system.SelectFirmware - Storage Controller.Download and install** CRITICAL ** Online ROM Flash Component for Windows (x64) - Smart Array H240ar, H240, H241, H244br, P244br, P440ar, P440, P441, and P840Version 1.34 (B) or later.Reboot the server for updates to take effect and hardware stability to be maintained.Until Smart Array Controller Firmware Version 1.34 (B) can be applied, reboot the system (or more than once if necessary) to restore normal operation of the drives.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to HP ProLiant Gen9 servers, use the following search string:+Advisory +ProLiant -"Software and Drivers" +Gen9
Operating Systems Affected:Linux - Enterprise Red Hat 5
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.