Any HP MSA P2000 G3 array using a variation of TS251xxx firmware may experience a controller terminating unexpectedly if a volume’s read ahead cache setting is enabled and using a value other than ‘default’. Controller failure events are recorded in the array’s system event log. This event can be viewed in the Storage Management Utility (SMU) or using the array’s CLI interface. This particular controller failure event will be similar to the event below:Page Fault p1: 0x3FBEFD8A, p2: 0x0000000, p3: 0x0000000, p4: 0x0000000 CThr: Cache
This issue affects HP P2000 G3 MSA Array Systems.
This issue will be addressed in a future firmware release.WorkaroundSee each volume’s read ahead cache setting. For any HP P2000 G3 MSA array volume’s read ahead cache setting that is enabled and set to a value other than the default value, change the volume’s read ahead cache setting back to the default setting. The read ahead cache setting is a dynamic setting and can be changed without affecting any hosts. If a controller has terminated unexpectedly and is in an offline state, restart the offline controller.
Operating Systems Affected:Not Applicable