IMPORTANT: The System ROM update provided in the Resolution is recommended to prevent the issues below from occurring. HP recommends performing this upgrade at the customer's earliest possible convenience. Neglecting to perform the recommended action and not performing the recommended resolution could result in the potential for subsequent errors to occur.Intel has identified a processor issue where Virtual Machines (VMs) running on VMware ESX 5.x or Microsoft Hyper-V may experience a Blue Screen of Death (BSOD) in a Windows virtual machine or a kernel panic in a Linux virtual machine when using VMware ESX 5.x or Microsoft Hyper-V. This issue affects Intel Xeon E5-2400 series v2, Intel Xeon E5-2600 series v2, Intel Xeon E5-4600 series v2, Intel Xeon E7-4800 series v2, and Intel Xeon E7-8800 series v2 processors.Intel has released an updated microcode for impacted processors that addresses this issue. Updated revisions of HP ProLiant System ROMs for impacted servers include this microcode. This issue is NOT unique to HP ProLiant servers and could impact any system utilizing affected processors if the updated microcode is not utilized.This issue does NOT affect servers configured with Intel Xeon E5-2400 series, Intel Xeon E5-2600 series, or Intel Xeon E5-4600 series processors. In addition, all ProLiant Gen8 server blades with 02/10/2014 version of the System ROMs supports the CloudSystem Matrix (CSM) versions: 7.3.1.0, 7.3.0.2, 7.3.0.1, 7.3.0.0, 7.2.2.1, 7.2.2.0, 7.2.1.2, 7.2.1.1, 7.2.0.3, 7.2.0.2, 7.1.2.4, 7.1.1.5, 7.1.0.4.
Any of the following HP ProLiant Gen8 server blades will be affected when configured with Intel Xeon E5-2400v2, Intel Xeon E5-2600v2, Xeon E5-4600 v2, Intel Xeon E7-4800 v2, or Intel Xeon E7-8800 v2 Processors and running an HP CloudSystem Matrix environment with a System ROM revision dated earlier than 02/10/2014:HP ProLiant BL420c Gen8 - I30HP ProLiant BL460c Gen8 - I31HP ProLiant BL660c Gen8- I32
This issue is corrected by updating the System ROM to the version dated 02/10/2014 for the CloudSystem Matrix environment.Download the 02/10/2014 System ROMs for each model of ProLiant Gen8 Server Blade in the EnvironmentIf the version of the CloudSystem Matrix environment requires using the SPP 2014.02.0(B) or the stand-alone smart components will be used to install and update the System ROMs, then use the instructions on the System ROM Download page. The HP SUM assisted instructions will only function with SPP 2014.02(B). The stand-alone component instructions will function with either SPP 2014.02.09(B) or 2013.09.0©) for the System ROMs of all Gen8 server blades in the enclosure.SPP 2014.02.0(B) supports CSM Versions 7.3.1.0, 7.3.0.2, 7.3.0.2, 7.2.2.1, 7.2.1.2, 7.2.0.3SPP 2013.09.0©) supports CSM Versions 7.3.0.1, 7.3.0.0, 7.3.0.1, 7.2.2.0, 7.2.1.1, 7.2.0.2, 7.1.2.4, 7.1.1.5, 7.1.0.4NOTE: If the version of the CMS environment requires SPP 2013.09.0 (C)andit is preferred to use the HP Smart Update Manager (HP SUM) assisted installment, then use the following steps (below) to update the System ROM:Step 1: Download theMatrix Versioning ToolDownload the Matrix Versioning Tool version 3.4 fromwww.hp.com/go/matrixcompatibility.Step 2: Download the MatrixConfig.xml file.Download the latest version of the ProLiant MatrixConfig.xmlfile. From www.hp.com//go/matrixcompatibility, click on the tab that corresponds to the appropriate Cloud System Matrix (CSM) version and download the ProLiant xml file.Step 3: Install Matrix Versioning ToolInstall the Matrix Versioning Tool version 3.4 onto the CMS.Double-click the installer file, for example, cp019311.exe.Click "Run" from the pop-up window.Click "Extract"Select or create a new directory to extract the file. Click "OK"Click "Close" on the installer window.Copy the xml files downloaded earlier to the directory where the Matrix Versioning Tool was extracted.Step 4: Use the Matrix Versioning Tool to put the enclosure in update mode.Pick one enclosure in the environment.Using cmd.exe, change directories to the directory where the Matrix Versioning Tool was placed. The directory displays.Enter the following command to put the versioning tool in update mode:"MatrixIDGUI.exe /update"Select "Accept" for the terms in the license agreement. The CloudSystem Matrix Version Tool's Welcome screen displays.Click "Next" The login screen displays.Enter the OA IP address and login credentials and click "Login" The environment's current version is displayed in Current CloudSystem Matrix version.Click "Submit" The Success window displays.Click "Exit" in the Success window. The enclosure is now in update mode.Step 5: Use the instructions included on the System ROM Download page to update the System ROMs for all the Gen 8 Blades in the enclosure.Step 6: Change the enclosure back to normal operating mode.Run the Matrix Versioning Tool with the /update option to take the enclosure out of update mode.Using cmd.exe, change directories to the directory where the Matrix Versioning Tool was placed. The directory displays.Enter the following command to take the versioning tool out of update mode:"MatrixIDGUI.exe /update"Click "Exit" in the Success window. The enclosure is no longer in update mode.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.