The HP Moonshot Tools for PowerShell bundle for the Converged System 100 (CS100) "Set-HPMoonshotNodeBoot" will falsely report a failure when executed on a Chassis Manager running version 1.20, included in the HP Moonshot Component Pack Version 2014.06.Set-HPMoonshotNodeBoot command output falsely reports the following error in PowerShell:Command Failed, please verify node rangeThe command is successfully sent to the Chassis Manager but is reported as a failure in Windows PowerShell:When Set-HPMoonshotNodeBoot is executed on Chassis Manager Version 1.11, the error does not occur:This issue only occurs when:HP Chassis Manager firmware is upgraded from Version 1.11 to Version 1.20ANDTheSet-HPMoonshotToolsNodeBootcommand is executed on the affected Chassis Manager via Windows PowerShell.This occurs because the HP Chassis Manager command output for "set node boot CxNy" has changed in Version 1.20 included in the HP Moonshot Component Pack 2014.06. The new command output from the Chassis Manager syntax has changed from "Cartridge #" to "#Cartridge." Due to the new command output of the Chassis Manager in version 1.20, the HP Moonshot Tools for PowerShell bundle for the CS100 "Set-HPMoonshotNodeBoot" will falsely report a failure when executed on this version of the Chassis Manager.
Any HP Moonshot chassis with:Chassis Manager Version 1.20ConvergedSystem 100 (CS100) for Hosted DesktopsHP Moonshot Component Pack 2014.06HP Moonshot Tools for PowerShell Version 1.1.7HP Moonshot Tools for PowerShell Version 1.0.8HP Moonshot Tools for PowerShell Version 1.1.4
TheSet-HPMoonshotNodeBootfailures reported when executed on Chassis Manager Version 1.20 are false and can be safely ignored. The Windows PowerShell command, even if executed on Chassis Manager 1.20, will be successfully sent and configured on the Chassis Manager.To prevent the false messages from occurring, download and use the HP Moonshot Tools for PowerShell Version 1.1.7 (or later) before installing Chassis Manager Version 1.20 (or later).HP Moonshot Tools for PowerShell Version 1.1.7 includes a fix for theSet-HPMoonshotNodeBootreported failures when executed on Chassis Manager Version 1.20 and is available at the following URL:http://h20565.www2.hp.com/portal/site/hpsc/public/psi/swdHome/?lang=en&cc=us&sp4ts.oid=6636568RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.