Loading...
Loading...
On HP ProLiant servers configured with HP Smart Array P212, P410, P410i, P411, P712m, or P812 Controllers running Firmware Version 6.40 (B) or earlier, the following erroneous error messages may be generated by the controller when the server is operating BELOW the specified operational temperature:HP Active Health System (AHS) LogSmart Array Controller temperature limit exceeded.....Controller temperature limit reached Controller=0 Sensor=2:2 Temp=255 Limit=65HP Onboard AdministratorCritical Temperature Threshold Exceeded
Any HP ProLiant server configured with an HP Smart Array P212, P410, P410i, P411, P712m, or P812 Controller running Firmware Version 6.40 (B) (or earlier).
If the server is operating at a temperature BELOW its specified operational limit when theseTemperature Exceedederror messages are generated, the messages are erroneous. The server temperature should be brought within operational limits, which should eliminate the erroneoustemperature limit exceededorCritical Temperature threshold exceedederror messages.Note:HP does not support systems in environments that cause them to operate below or above the specified temperature limits.This will be corrected in a future version of the HP Smart Array Controller firmware. This advisory will be updated when more information becomes available.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to HP Smart Array Pxxx Controllers, use the following search string:+Advisory +ProLiant -"Software and Drivers" +"Smart Array P" +Controller
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.