On an HP c-Class BladeSystem, the HP D2200sb Storage Blade and its partnered server blade may be powered down by the Onboard Administrator (OA) after sending a message of its condition. The HP Smart Array Diagnostics Utility only monitors specific drive conditions. The Smart Array controller passes the hard drive message to the firmware running in the Onboard Administrator (OA), which misinterprets the message as being in a critical condition and shuts down the storage blade and its partnered server blade.When this occurs, the HP Onboard Administrator (OA) system log will contain the following message: "OA: Blade X thermal state is CRITICAL," where X in this message is the storage blade bay. The Smart Array Diagnostics Utility will not have any over-temperature conditions logged.The storage blade will power back on as expected, but the partnered server blade will not because the power-on ordering requirements have been violated. To restart it, the power-on sequence requires that the storage blade must be inserted and powered on before its partnered server blade is.The issue applies to storage server blades partnered with server blades running any HP Smart Array controller firmware version earlier than version 6.46. However, this issue may be seen more frequently if third-party drive monitoring software is used.
Any HP D2200sb Storage Blade partnered with server blades running HP Smart Array firmware versions earlier than version 6.46. This issue has been observed in the D2200SB Storage Blades using specific hard drive model: 900GB 2.5" 10K HDD (619291-B21/652589-B21) drives (model #EG0900FCVBL). However, this issue may also be seen with other storage blade and hard drive combinations.
This issue is corrected by upgrading to HP Smart Array Controller Firmware Version 6.46. When the server is connected to the internet, update the Smart Array controller firmware from the following directory:https://downloads.hpe.com/pub/softlib2/software1/sc-linux-fw-array/p1997486963/v94858/CP022603.md5ACCESS DENIED ERRORS:Click Here if You Encounter Access Denied Errors with the FTP link.Also, uninstalling any third-party drive monitoring software may prevent this issue. Most third-party drive monitoring software merely duplicates functionality already contained within the Smart Array firmware.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.
Operating Systems Affected:Linux - Enterprise Red Hat 5
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.