The HP Lights-Out Online Configuration Utility (HPONCFG) fails to install on a ProLiant server using HP Smart Update Manager (HP SUM) 5.3.5 on a Windows 2003 32-bit or 64-bit Operating System.During the installation, the following error message will be displayed, indicating a failed dependency of HP ProLiant iLO 3/iLO 4 Channel Interface Driver:HP Lights-Out Online Configuration Utility, HPONCFG Version 4.2.0.0, has a dependency on the HP ProLiant iLO 3/iLO 4 Channel Interface Driver Version 3.9.0.0. Therefore, HPONCFG can only be installed if the supported Channel Interface driver is installed on the same system. Since HP ProLiant iLO 3/iLO 4 Channel Interface Driver 3.9.0.0 does not support Windows 2003 32- bit and 64- bit Operating Systems, HPONCFG fails to install in this configuration. The issue occurs when the following steps are performed:Mount the HP SUM 5.3.5 .iso file.Navigate to Path hp/swpackages/HPSUM.exeRun HPSUM.exeDiscover all the components. HP SUM fails to discover HPONCFG 4.2.0.0. Since HPONCFG has dependency on HP ProLiant iLO 3/iLO 4 Channel Interface Driver 3.9.0.0
Any ProLiant server with HP Integrated Lights Out 4 Firmware Version 1.30 (or earlier) or HP Integrated Lights Out 3 Firmware Version 1.60 (or earlier), running Microsoft Windows Server 2003 in the configuration detailed above.
To correct this issue, perform the following:Mount the HP SUM 5.3.5 .iso file.Navigate to Path hp/swpackages/Install HP ProLiant iLO 3/iLO 4 Channel Interface Driver 3.5.0.0 manually on Windows 2003 32-bit and 64- bit Operating SystemsExtract HPONCFG 4.2.0.0 from the HP Service Pack for ProLiant (SPP).iso file.Install HPONCFG 4.2.0.0 manually on the Windows 2003 32 bit and 64 bit Operating Systems. HP Lights-Out Online Configuration Utility Version 4.2.0.0 will install successfully.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.
Operating Systems Affected:Microsoft Windows Server 2003
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.